equipment noise eminating from the air handler. These treatments can produce a quieter installation, particularly in the heated space. However, they can increase the pressure drop in the duct system. Care must be taken to maintain the proper maximum pressure rise across the air handler, temperature rise and flow rate. This may mean increasing the duct size and/or reducing the blower speed. These treatments must be constructed and installed in accordance with NFPA and SMACNA construction standards. Consult with local codes for special requirements. For best sound performance, be sure to install all the needed gaskets and grommets around penetrations into the air handler, such as for electrical wiring.

Air handler INSTALLATION

The HMG**F1E, HMG**X1E & HCG**V1E Series Air Handler is shipped ready for vertical upflow installation and is approved for attic, basement, alcove/closet or crawlspace installation with zero clearance to combustibles. See Table 1 (page 4) for required installation clearances. This appliance is approved only for indoor use.

The unit must be leveled at installation and attached to a properly installed duct system.

The surface that the air handler is mounted on must provide sound physical support of the unit.

The air handler must be installed so that all electrical components are protected from water.

If a louvered door is installed across the front of this unit, the appliance must be mounted flush or behind front edge of finished wall.

Always reinstall the doors on the air handler after servicing or cleaning/changing the filters.Do not operate the air handler without all doors and covers in place.

Packaging Removal

Remove the shipping crate and User’s Manual from the equipment. When removing the crate, use extra care so tubing connectios are not damaged. Do not pull on the coils upper tubes.

Mounting Applications

Vertical only air handlers are factory ready for upflow applications. These units may be applied in downflow applications when applied with the appropriate field kit.

Factory ready horizontal air handlers may be applied in upflow or horizontal-left and -right discharge applications. These units may also be applied in downflow discharge when applied with the appropriate field kit as specified in the units Technical Specifications.

Through-the-floor installations require a 1/4” thick noncombustible resilient gasket to be used whenever the supply or return air ducts pass through the floor.The gasket should be positioned between the duct, unit, and floor.

Horizontal

Drain Pan

Return

Air

Figure 1. Upflow Installation

Upflow Installations

All air handlers are factory shipped, ready for upflow installation. The horizontal drain pan may be removed from the air handler when installing the unit in an upflow configuration. All return air must enter from the bottom of the unit. A typical upflow unit is shown in Figure 1.

Downflow Installations

The downflow accessory kit (SeeTechnical Specifications) is required for downflow applications. Instructions for installing the downflow accessory kit are included with the kit.It is recommended that the accessory be installed prior to installing the unit. All return air in downflow applications must enter through the top of the unit. A typical installation of the unit in a downflow application is shown in Figure 2.

Cabinet

Tube

Close-off

Plate

Adaptor Kit

Coil

Figure 2. Downflow Installation

6

Page 6
Image 6
Heat Controller HMG**X1E Air handler Installation, Packaging Removal, Mounting Applications, Downflow Installations

HMG**X1E, HCG**V1E, HMG**F1E specifications

The Heat Controller series, comprising models HMG**F1E, HCG**V1E, and HMG**X1E, showcases advanced heating and cooling technologies designed for optimal comfort and energy efficiency in residential and commercial settings. Each model is equipped with a range of features that cater to diverse user needs while maintaining excellent performance.

The HMG**F1E model stands out with its sleek design and compact size, making it ideal for smaller spaces. It utilizes inverter technology, which enables the unit to operate at variable speeds for greater efficiency and reduced energy consumption. This model also comes with a user-friendly remote control, allowing for easy adjustments of temperature settings and operational modes without the need to manually interact with the unit itself. The HMG**F1E is equipped with a filtration system that improves indoor air quality by removing dust and allergens, providing a more comfortable living environment.

In contrast, the HCG**V1E model is designed with versatility in mind, offering both heating and cooling functions. This unit features a programmable thermostat, allowing users to set their preferred temperatures for different times of the day. The HCG**V1E is manufactured with durable materials that ensure longevity and reliability under various weather conditions. Additionally, it provides whisper-quiet operation, ensuring minimal disturbance to indoor activities. The energy-efficient operation and smart climate control technology contribute to significant savings on energy bills.

Finally, the HMG**X1E model is known for its cutting-edge smart technology integration. This model can be connected to smart home systems, enabling users to control the unit from their smartphones or tablets. It features advanced sensors that detect occupancy and adjust heating and cooling accordingly, optimizing energy usage in real-time. The HMG**X1E also incorporates an eco-friendly refrigerant, aligning with modern environmental standards while delivering exceptional performance.

Overall, the Heat Controller series with models HMG**F1E, HCG**V1E, and HMG**X1E redefine comfort and efficiency. With their combination of innovative technologies, user-friendly features, and sustainable designs, they are perfect for anyone seeking reliable temperature control solutions for their spaces.