Heat Controller, Inc. | HTV/HTD/HTH SERIES | Engineering Design Guide |
|
|
|
Heat ControllerTwoGeoMaxStage Geothermal2 n GeothermalHeat PumpHeatSystemsPump Systems
Dimensions – Vertical Upflow
|
|
|
|
| Discharge Connection |
|
|
| Return Connection |
| ||||
|
|
|
|
|
|
| Standard Deluxe Filter Rack |
| ||||||
Vertical |
| Duct Flange Installed (+/- 0.10 in, +/- 2.5mm) |
|
| ||||||||||
|
| (+/- 0.10 in, +/- 2.5mm) |
| |||||||||||
|
|
|
|
|
|
|
| |||||||
Upflow |
|
|
|
|
|
|
|
|
|
|
|
| ||
| M |
| O | P | Q |
|
| S | T |
|
| |||
Model |
|
|
|
|
|
| ||||||||
|
|
|
| Left | N | Supply | Supply | Right | R |
| Return | Return |
| U |
|
|
|
| Return |
| Width | Depth | Retuen |
|
| Depth | Height |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0246 |
|
| in | 7.8 | 5.8 | 14.0 | 14.0 | 4.9 | 1.7 |
| 22.2 | 26.2 |
| 1.5 |
|
| cm | 18.3 | 14.8 | 35.6 | 35.6 | 12.4 | 4.2 |
| 56.4 | 66.4 |
| 3.9 | |
|
|
|
|
| ||||||||||
|
|
| in | 6.4 | 6.3 | 18.0 | 18.0 | 5.3 | 2.1 |
| 27.1 | 26.1 |
| 1.5 |
0368 |
|
|
|
| ||||||||||
|
| cm | 16.1 | 16.0 | 45.7 | 45.7 | 13.5 | 5.4 |
| 68.9 | 66.4 |
| 3.9 | |
|
|
|
|
| ||||||||||
|
|
| in | 6.4 | 6.3 | 18.0 | 18.0 | 5.3 | 2.1 |
| 27.1 | 30.1 |
| 1.5 |
0489 |
|
|
|
| ||||||||||
|
| cm | 16.1 | 16.0 | 45.7 | 45.7 | 13.5 | 5.4 |
| 68.9 | 76.5 |
| 3.9 | |
|
|
|
|
| ||||||||||
0604 |
|
| in | 6.4 | 6.3 | 18.0 | 18.0 | 5.3 | 2.1 |
| 27.1 | 34.1 |
| 1.5 |
|
| cm | 16.1 | 16.0 | 45.7 | 45.7 | 13.5 | 5.4 |
| 68.9 | 86.7 |
| 3.9 | |
|
|
|
|
| ||||||||||
0702 |
|
| in | 6.4 | 6.3 | 18.0 | 18.0 | 5.3 | 2.1 |
| 27.1 | 34.1 |
| 1.5 |
|
| cm | 16.1 | 16.0 | 45.7 | 45.7 | 13.5 | 5.4 |
| 68.9 | 86.7 |
| 3.9 | |
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P N
O | Front |
|
QAir Coil Side
Top
|
|
|
| Field Installed | Access Panels |
|
|
|
|
| Discharge Flange |
| |
|
|
|
|
|
| |
|
|
| Deluxe Filter Bracket |
|
|
|
| Legend |
|
|
|
|
|
CAP=Control Access Panel |
|
|
|
|
| |
CSP=Compressor Service Panel |
|
|
|
| ||
BSP=Blower Service Panel |
|
|
|
|
| |
ASP=Alternate Service Panel |
|
|
|
| ||
| B |
| Air Coil |
|
|
|
|
|
|
| ASP |
| |
N | P |
|
|
|
| |
|
| BSP |
|
| ||
|
|
|
|
|
| |
| Front | O |
|
|
| 2' (61cm) |
| A |
|
|
| Optional | |
|
|
|
|
| Service | |
|
|
|
|
|
| Access |
|
|
| CSP |
| ASP | Left Rtn |
|
| M | CAP |
| (right | |
| Air Coil Side |
|
| Opposite) | ||
|
|
|
|
|
Top
U
T
C
S
Residential
Filter Rack
Shown
R R
U
Air Coil
T
C
S
Residential
Filter Rack
Shown
2' (61cm)
Service
Air Coil
Power Supply 3 / 4" [19.1mm] HV Knockout
1 / 2" [12.7mm]
Knockout
Isometric
View
1.00 [25.4 mm]
1.68 [42.7 mm]
|
| Condensate |
|
| 3 / 4" Glue |
|
| (PVC Socket) |
1.63 | CAP | 4 |
[41.4 mm] |
| 3 |
|
|
|
|
|
|
| 1.18 [30.0 mm] |
|
|
|
|
|
|
|
|
| |
| ASP |
|
| CSP |
| ||
Front | Back | Back |
| ||||
|
|
|
|
|
|
|
|
| Right Return Right View |
|
| Left Return Left View |
| ||
| - Filter Rack Knife Edge |
|
| - Filter Rack Knife Edge |
|
Low Voltage
1 / 2" [12.7mm]
LV Knockout
CSP
Front
| 2 |
| F G |
J K L | 5 |
| |
1 | D | H E | |
|
|
|
8