Heat Controller HTD SERIES Dimensions - Vertical Upflow, Htv/Htd/Hth Series, Discharge Connection

Models: HTV SERIES HTH SERIES HTD SERIES

1 29
Download 29 pages 52.49 Kb
Page 9
Image 9
Discharge Connection

Heat Controller, Inc.

HTV/HTD/HTH SERIES

Engineering Design Guide

 

 

 

Heat ControllerTwoGeoMaxStage Geothermal2 n GeothermalHeat PumpHeatSystemsPump Systems

Dimensions – Vertical Upflow

 

 

 

 

 

Discharge Connection

 

 

 

Return Connection

 

 

 

 

 

 

 

 

Standard Deluxe Filter Rack

 

Vertical

 

Duct Flange Installed (+/- 0.10 in, +/- 2.5mm)

 

 

 

 

(+/- 0.10 in, +/- 2.5mm)

 

 

 

 

 

 

 

 

 

Upflow

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

O

P

Q

 

 

S

T

 

 

Model

 

 

 

 

 

 

 

 

 

 

Left

N

Supply

Supply

Right

R

 

Return

Return

 

U

 

 

 

 

Return

 

Width

Depth

Retuen

 

 

Depth

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0246

 

 

in

7.8

5.8

14.0

14.0

4.9

1.7

 

22.2

26.2

 

1.5

 

 

cm

18.3

14.8

35.6

35.6

12.4

4.2

 

56.4

66.4

 

3.9

 

 

 

 

 

 

 

 

in

6.4

6.3

18.0

18.0

5.3

2.1

 

27.1

26.1

 

1.5

0368

 

 

 

 

 

 

cm

16.1

16.0

45.7

45.7

13.5

5.4

 

68.9

66.4

 

3.9

 

 

 

 

 

 

 

 

in

6.4

6.3

18.0

18.0

5.3

2.1

 

27.1

30.1

 

1.5

0489

 

 

 

 

 

 

cm

16.1

16.0

45.7

45.7

13.5

5.4

 

68.9

76.5

 

3.9

 

 

 

 

 

0604

 

 

in

6.4

6.3

18.0

18.0

5.3

2.1

 

27.1

34.1

 

1.5

 

 

cm

16.1

16.0

45.7

45.7

13.5

5.4

 

68.9

86.7

 

3.9

 

 

 

 

 

0702

 

 

in

6.4

6.3

18.0

18.0

5.3

2.1

 

27.1

34.1

 

1.5

 

 

cm

16.1

16.0

45.7

45.7

13.5

5.4

 

68.9

86.7

 

3.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P N

O

Front

 

QAir Coil Side

Top View-Right Return

 

 

 

 

Field Installed

Access Panels

 

 

 

 

 

Discharge Flange

 

 

 

 

 

 

 

 

 

 

Deluxe Filter Bracket

 

 

 

 

Legend

 

 

 

 

 

CAP=Control Access Panel

 

 

 

 

 

CSP=Compressor Service Panel

 

 

 

 

BSP=Blower Service Panel

 

 

 

 

 

ASP=Alternate Service Panel

 

 

 

 

 

B

 

Air Coil

 

 

 

 

 

 

 

ASP

 

N

P

 

 

 

 

 

 

BSP

 

 

 

 

 

 

 

 

 

Front

O

 

 

 

2' (61cm)

 

A

 

 

 

Optional

 

 

 

 

 

Service

 

 

 

 

 

 

Access

 

 

 

CSP

 

ASP

Left Rtn

 

 

M

CAP

 

(right

 

Air Coil Side

 

 

Opposite)

 

 

 

 

 

Top View-Left Return

U

T

C

S

Residential

Filter Rack

Shown

R R

U

Air Coil

T

C

S

Residential

Filter Rack

Shown

2' (61cm)

Service

Air Coil

Power Supply 3 / 4" [19.1mm] HV Knockout

1 / 2" [12.7mm]

Knockout

Isometric

View

1.00 [25.4 mm]

1.68 [42.7 mm]

 

 

Condensate

 

 

3 / 4" Glue

 

 

(PVC Socket)

1.63

CAP

4

[41.4 mm]

 

3

 

 

 

 

 

 

 

1.18 [30.0 mm]

 

 

 

 

 

 

 

 

 

 

ASP

 

 

CSP

 

Front

Back

Back

 

 

 

 

 

 

 

 

 

 

Right Return Right View

 

 

Left Return Left View

 

 

- Filter Rack Knife Edge

 

 

- Filter Rack Knife Edge

 

Low Voltage

1 / 2" [12.7mm]

LV Knockout

CSP

Front

 

2

 

F G

J K L

5

 

1

D

H E

 

 

 

Front-View

8

Page 9
Image 9
Heat Controller HTD SERIES, HTH SERIES, HTV SERIES Dimensions - Vertical Upflow, Htv/Htd/Hth Series, Discharge Connection