MGD Series Gas Furnace

MGD Series Gas Furnace

 

 

 

 

 

 

Installation Instructions

SPECIFICATIONS

 

 

 

 

 

 

 

 

 

80 AFUE- AUTOMATIC HOT SURFACE

 

 

 

 

 

 

 

 

IGNITION

 

 

 

 

 

 

 

 

 

Model No.

MGD60-E3A

MGD75-E3A

MGD90-E3A

 

 

MGD60-E5A

MGD75-E5A

MGD90-E5A

Input, BTUH

60,000

75,000

90,000

 

 

60,000

 

75,000

90,000

Output, BTUH

48,000

60,000

72,000

 

 

48,000

 

60,000

72,000

AFUE, %

80.0

81.0

80.0

 

 

80.0

 

81.0

80.0

With A-Coil Cabinet

YES

YES

YES

 

 

YES

 

YES

YES

Ignition Type

Auto-Elect

Auto-Elect

Auto-Elect

 

 

Auto-Elect

 

Auto-Elect

Auto-Elect

Air Temperature Rise, Range-F

40-70

45-75

50-80

 

 

40-70

 

45-75

50-80

Blower

10 X 8, 1/3 HP, 3 SPD

 

 

10 X 8, 3/4 HP, 4 SPD

Designed Max Outlet Air Temp-F

 

 

 

165 °

 

 

 

Max. External SP (Duct),In. W.C.

 

 

.30 Heating

 

 

 

Factory Equipped Fuel

 

Natural Gas (Factory Equipped) - LP Orfice Furnished

 

High Altitude

For elevations above 2,000 feet, reduce input 4% for each 1,000 ft. elevation above sea level

Furnace Flue Pipe

Must Use RJS Roof Jack for Sloped Roof or RJF Roof Jack for Flat Roof

Gas Connection

 

 

1/2" FPT

 

 

 

Electric Service

 

 

115 VAC, 60 HZ, 1 PH

 

 

 

Fuse or Circuit Breaker

 

 

15 Amp

 

 

 

Thermostat Circuit

 

 

24VAC, 60Hz, 40VA

 

 

 

Filters

 

 

1-16"x40"x1" Washable

 

 

 

PRODUCT CODE

 

 

 

 

 

 

PART NO.

DESCRIPTION

NOTES

 

 

 

90-RJF1729-AL

Body, Roof Jack, Gas-FLAT

Height 94 1/2 X 106 1/2

 

 

 

90-RJF2551-AL

Body, Roof Jack, Gas-FLAT

Height 102 1/2 X 128 1/2

 

 

 

90-RJS1729-AL

Body, Roof Jack, Gas-SLOPE 3/12

Height 94 1/2 X 106 1/2

 

 

 

90-RJS2551-AL

Body, Roof Jack, Gas-SLOPE 3/12

Height 102 1/2 X 128 1/2

 

 

 

90-RJS3868-AL

Body, Roof Jack, Gas-SLOPE 3/12

Height 115 1/2 X 145 1/2

 

 

 

90-RJS6399-AL

Body, Roof Jack, Gas-SLOPE 3/12

Height 140 1/2 X 176 1/2

 

 

 

90-RJCRWN-AL

Crown, Roof Jack, Gas

Use w/ Gas Roof Jack Body

 

 

 

90-TRN-RNG

Ceiling Trim Ring, Roof Jack

Trim out to inside RJ - Pipe

 

 

 

90-OUTXT16-AL

Roof Jack Outdoor Extension - Gas 16"

Extend pipes / crown - 16 in.

 

 

 

90-INXST10-AL

Roof Jack Indoor Extension - Gas 10"

Extend pipes / crown - 10 in.

 

 

 

90-RJS56

5-6/ 12 Slope, Roof Saddle Adapter

Add to RJS 3/12 Roof Jack

 

 

 

90-DCU0-01

86AA0013 Duct Conn + 87FB0005 Flr Base

Floor to Duck 1 in. - 4 in.

 

 

 

90-DCU0-02

86AA0014 Duct Conn + 87FB0005 Flr Base

Floor to Duck 6 in. - 8 in. STD

 

 

 

90-DCU0-03

86AA0015 Duct Conn + 87FB0005 Flr Base

Floor to Duck 8 in. - 12 in.

 

 

 

90-CABEXT4

White, Top, Cabinet Extender Plate

Fill alcove 76" top opening

 

 

 

87-1008-3/12A1

A/C Blower, 3 Speed - 1/3 HP

2 - 4 Ton A/C

 

 

 

87-1008-4/16A1

A/C Blower, 3 Speed - 3/4 HP

2 - 5 Ton A/C

 

 

 

 

 

 

Heat Controller, Inc. Jackson, MI 49203

MGD Installation Instructions 2

Page 2
Image 2