Connecting the Cable between Indoor Unit and Outdoor Unit
![](/images/new-backgrounds/1003094/309439xi2.webp)
![](/images/new-backgrounds/1003094/309439xi3.webp)
Methods
of
connecting
the![](/images/new-backgrounds/1003094/309439xi8.webp)
cable![](/images/new-backgrounds/1003094/309439xi10.webp)
![](/images/new-backgrounds/1003094/309439xi11.webp)
![](/images/new-backgrounds/1003094/309439xi12.webp)
![](/images/new-backgrounds/1003094/309439xi13.webp)
![](/images/new-backgrounds/1003094/309439xi14.webp)
![](/images/new-backgrounds/1003094/309439xi15.webp)
![](/images/new-backgrounds/1003094/309439xi16.webp)
![](/images/new-backgrounds/1003094/309439xi17.webp)
![](/images/new-backgrounds/1003094/309439xi18.webp)
![](/images/new-backgrounds/1003094/309439xi19.webp)
![](/images/new-backgrounds/1003094/309439xi20.webp)
![](/images/new-backgrounds/1003094/309439xi21.webp)
![](/images/new-backgrounds/1003094/309439xi22.webp)
![](/images/new-backgrounds/1003094/309439xi23.webp)
![](/images/new-backgrounds/1003094/309439xi24.webp)
![](/images/new-backgrounds/1003094/309439xi25.webp)
![](/images/new-backgrounds/1003094/309439xi26.webp)
![](/images/new-backgrounds/1003094/309439xi27.webp)
![](/images/new-backgrounds/1003094/309439xi28.webp)
![](/images/new-backgrounds/1003094/309439xi29.webp)
![](/images/new-backgrounds/1003094/309439xi30.webp)
![](/images/new-backgrounds/1003094/309439xi31.webp)
![](/images/new-backgrounds/1003094/309439xi32.webp)
![](/images/new-backgrounds/1003094/309439xi33.webp)
![](/images/new-backgrounds/1003094/309439xi34.webp)
![](/images/new-backgrounds/1003094/309439xi35.webp)
![](/images/new-backgrounds/1003094/309439xi36.webp)
![](/images/new-backgrounds/1003094/309439xi37.webp)
![](/images/new-backgrounds/1003094/309439xi38.webp)
![](/images/new-backgrounds/1003094/309439xi39.webp)
![](/images/new-backgrounds/1003094/309439xi40.webp)
![](/images/new-backgrounds/1003094/309439xi41.webp)
![](/images/new-backgrounds/1003094/309439xi42.webp)
![](/images/new-backgrounds/1003094/309439xi43.webp)
![](/images/new-backgrounds/1003094/309439xi44.webp)
![](/images/new-backgrounds/1003094/309439xi45.webp)
(1)Remove
(2)Pull the connection cable through conduit.
(3)After conduit is through the panel, secure the nut on the opposite side of panel.
(4)Pass the connection cable through the hole.
(5)Properly connect the cable onto the terminal
block.
(6) Secure the connection cable with cord clamp Lock nut provided on the unit to reduce strain at the
terminal when the connection cable is pulled outside up to a 35 pound weight
G |
Terminal block
Cord clamp
Cap(Reuse)
Hole
(for low voltage line) Cap(Remove)
Taping
(for sealing)
WARNING: Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also exist. Therefore, be sure all wiring is tightly connected.
When connecting each power wire to the corresponding terminal, follow instructions "How to connect wiring to the terminals" and fasten the wire tightly using the screw on of the terminal plate.
How to connect wiring to the terminals
For strand wiring
(1)Cut the wire end with a wire cutter or wire- cutting pliers, then strip the insulation to expose the strand wiring about 10 mm(3/8").
(2)Using a screwdriver, remove the terminal screw(s) on the terminal plate.
(3)Using a round terminal fastener or pliers, securely clamp each stripped wire end with a round terminal.
(4)Position the round terminal wire, and replace by tightening the terminal screw using a screwdriver.
Power supply line | Conduit panel | Low voltage line |
(1ø, 230/208V) |
| (connecting cable) |
High voltage
Strand wire
mm(3/8") | Round |
Strip 10 | terminal |
|
| Low voltage |
|
|
Loosening the | Fastening the |
terminal block | wire tightly |
screw |
|
Connecting cable
20Wall Mounted