Heat Controller MMH18DA-1, MMC18DA-1 manual Insulating the Pipe and Special Piping Applications

Models: MMH18DA-1 MMH24DA-1 MMC24DA-1 MMC36TA-1 MMH36TA-1 MMC18DA-1

1 28
Download 28 pages 40.65 Kb
Page 23
Image 23

Checking the Drainage, Insulating the Pipe and Special Piping Applications

InsulatingthePipeandSpecialPipingApplications

Insulate the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vinyl tape.

If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately.

In cases where the outdoor unit is installed below the indoor unit perform the following:

1.Tape the piping, drain hose and connecting cable from down to up.

2.Secure the taped piping along the exterior wall using saddle or equivalent.

In cases where the Outdoor unit is installed above the Indoor unit perform the following.

1.Tape the piping and connecting cable from down to up.

2.Secure the taped piping along the exterior wall. Form a trap to prevent water entering the room.

3.Secure the piping onto the wall using a saddle or equivalent.

Seal a small

 

opening around

 

the pipings with

Taping

gum type sealant.

Drain hose

 

Plastic

Pipings

band

Connecting

 

 

cable

 

Power supply

 

cord

Trap is required to prevent water from entering into electrical parts.

Seal a small opening around the pipings with gum type sealant.

Trap

Trap

Installation Manual 23