Heat Controller SMH 09 Installation Parts, Anchoring the Outdoor Unit, Heat Controller, Inc

Models: SMH 09 SMA/SMH 09/12 SMA 12 SMH 12

1 14
Download 14 pages 16.49 Kb
Page 3
Image 3
Installation Parts

Heat Controller, Inc.

INSTALLATION INSTRUCTIONS

SMA/SMH 09/12

Installation Parts

Please install the accessories attached with unit correctly according to this installation manual.

Part No.

Name of Part

 

Quantity

1

Installation Plate

 

1

2

Mounting Screw A (ST3.9x25-C-H)

8

3

Anchor

 

8

 

 

Liquid side

o 1/4"

 

 

 

 

 

 

4

Refrigerant Pipe

Gas Side

o 3/8" (<12,000 Btu/h)

 

 

 

o 1/2" (≥12,000 Btu/h)

 

 

 

 

 

 

 

 

 

 

5

Remote Controller

 

1

6

Seal*

 

1

7

Drain Elbow*

 

1

* See outdoor installation instructions

**Cautions on remote controller installation

Keep the remote controller at least 3 feet from the nearest TV set or stereo equipment to advoid possible electronic interference.

Do not leave the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove.

Ensure that the positive and negative poles are correct when inserting batteries into the remote controller.

Anchoring the Outdoor Unit

The outdoor unit should not be exposed to strong winds

Anchor the outdoor unit with o1/4" or 5/16" anchor bolts

12000Btu/h

"

"

12000Btu/h

"

"

Note:

1.Be sure sides A, B, and C are free from block- age/obstacles to allow sufficient clearance for air flow and maintenance.

2.When the outdoor unit is higher than the indoor unit, to prevent rain from flowing inside, make a “U-bend” trap in the line.

3.The illustrations are only sketches. Actual units may be slightly different.

6 Seal

7

Drain

 

Elbow

**

UBend example

2

Page 3
Image 3
Heat Controller SMH 09 Installation Parts, Anchoring the Outdoor Unit, Heat Controller, Inc, Installation Instructions