3. Indoor Unit Installation

SMA/SMH 09/12

INSTALLATION INSTRUCTIONS

Heat Controller, Inc.

3. Indoor Unit Installation

A.

B. Place the upper lip at the back of the indoor unit onto the up- per hook of the installation plate. Move the indoor unit from side to side to see that is is secured onto the hook of the installation plate.

C. Push the lower part of the indoor unit up to the wall. Then move the indoor unit from side to side and up and down to ensure it is secured to the installation plate.

D. Piping can easily be installed by placing a piece of foam between the unit and the wall to assist in holding the unit away from the wall during installation.

4.Electrical Work

Connect unit to a dedicated circuit.

Refer to the unit’s rating plate from proper supply voltage.

A.

B.

C.

D.

E. All wiring to the unit and interconnecting between indoor and out- door units must comply with local and national electrical codes.

F.Do not exceed the power code by splicing.

G.Voltage should be in range of 90%~110% of unit’s voltage.

H.The indoor unit is powered through the interconnecting cable. The indoor unit requires no separate power source.