10
DIMENSIONAL DIAGRAM
Model UDual Aire Reach In Unit CoolerAPPLICATION
The U unit cooler is used wherever a small, compact unit is
required. It can be mounted on the ceiling or wall. The model
U unit draws air through the front and discharges it out both
sides to insure proper distribution of cool air and thus maintain
a uniform box temperature.
FEATURES
•Textured aluminum cabinet.
•Full collar aluminum fins on expanded copper tubes.
• Detachable drain pan that is easy to clean.
•Molded 3-prong motor connector to save installation time
and expense.
•Motors are thermally protected and permanently
lubricated.
•Optional coated coil available (Model UK) for optimum
protection in corrosive environments.
•All sizes UL-component recognized and NSF approved.
U (K) 09 0
0 = 115/1/60
1 = 208-230/1/60
U = Dual Aire
Unit Cooler
K = Coated Coil
(Optional)
Size
NOMENCLATURE
MOTOR DATA
CONNECTIONS (In.)
APPROX.
MODEL
BTUH CAPACITY
115/1/60V 208-230/1/60V COIL SHIPPING
U10°TD 15°TD CFM
TOTAL FLA TOTAL FLA
INLET SUCTION WT. (LBS.)
09 850 1275 190 .45 .55 1/2 FN 3/8 ID 9
12 1150 1725 250 .45 .55 1/2 FN 3/8 ID 10
15 1500 2250 310 1.10 .55 1/2 FN 3/8 ID 14
Performance/Electrical Data
PHYSICAL DATA
MODEL DIMENSIONS (In.)
UHWDABC
09 8 1/211 1/28 7/8643
1/2
12 8 1/217 1/28 7/812 4 9 1/2
15 9 1/217 1/210 7/812 4 9 1/2