Heatcraft Refrigeration Products ELC/EFC Model GLC Hot Gas Defrost, Physical Data, No. of, Drain

Models: GLC ELC/EFC RLC

1 20
Download 20 pages 4.37 Kb
Page 11
Image 11
Model GLC Hot Gas Defrost

Physical Data

Model GLC Hot Gas Defrost

6 Fins Per Inch

4 Fins Per Inch

 

 

 

 

Connections (in.)

 

 

Approx.

 

 

 

 

 

 

Net Wt.

 

No. of

 

 

 

 

 

 

Model

Coil

 

External

 

Side

Hot Gas

 

 

Fans

Suction

Drain

 

 

 

Inlet

Equalizer

Port

Pan Conns.

lbs.

kg

 

 

ID

MPT

 

 

ODF

OD

OD

OD

 

 

 

 

 

 

 

 

GLC035

1

5/8

5/8

1/4

3/4

3/8

5/8

26

12

GLC040

1

5/8

5/8

1/4

3/4

3/8

5/8

28

13

GLC047

1

5/8

5/8

1/4

3/4

3/8

5/8

31

15

 

 

 

 

 

 

 

 

 

 

GLC065

2

5/8

5/8

1/4

3/4

3/8

5/8

45

21

GLC075

2

5/8

7/8

1/4

3/4

3/8

5/8

47

22

GLC090

2

7/8

7/8

1/4

3/4

3/8

5/8

50

23

 

 

 

 

 

 

 

 

 

 

GLC120

3

7/8

7/8

1/4

3/4

3/8

5/8

62

29

GLC140

3

7/8

7/8

1/4

3/4

3/8

5/8

64

30

GLC160

4

7/8

1-1/8

1/4

3/4

3/8

5/8

83

38

 

 

 

 

 

 

 

 

 

 

GLC180

4

1-1/8

1-1/8

1/4

3/4

3/8

5/8

86

40

GLC200

5

1-1/8

1-1/8

1/4

3/4

3/8

5/8

103

47

GLC240

6

1-1/8

1-1/8

1/4

3/4

3/8

5/8

123

56

 

 

 

 

 

 

 

 

 

 

GLC280

6

1-1/8

1-1/8

1/4

3/4

3/8

5/8

126

57

GLC041

1

5/8

5/8

1/4

3/4

3/8

5/8

30

14

GLC068

2

5/8

7/8

1/4

3/4

3/8

5/8

46

21

 

 

 

 

 

 

 

 

 

 

GLC080

2

5/8

7/8

1/4

3/4

3/8

5/8

49

23

GLC102

3

7/8

7/8

1/4

3/4

3/8

5/8

61

28

GLC136

4

7/8

1-1/8

1/4

3/4

3/8

5/8

82

38

 

 

 

 

 

 

 

 

 

 

GLC170

5

7/8

1-1/8

1/4

3/4

3/8

5/8

102

47

GLC204

6

7/8

1-1/8

1/4

3/4

3/8

5/8

122

56

GLC235

6

1-1/8

1-1/8

1/4

3/4

3/8

5/8

125

57

 

 

 

 

 

 

 

 

 

 

The standard design for the Chandler Low Profile Evaporator incorporates a hot gas loop in the drain pan. Utilizing a hot gas loop is ideal for hot gas defrost applications where high temperature gas can be maintained to defrost both the evaporator drain pan and coil.

For applications where cooler (lower) temperature hot gas is used for defrosting, Chandler offers optional electric heater elements in the drain pan to ensure quick and efficient defrost of the drain pan allowing condensate to drain quickly, saving the hot gas for efficient evaporator coil defrost.

If the optional electric heating element drain pan is preferred, please specify when ordering, there is no additional charge.