Model GLC Hot Gas Defrost  60 Hz

Performance Data

Model GLC Hot Gas Defrost 60 Hz

 

 

Capacity

 

Fan Data

 

 

Model

10°F TD

6°C TD

 

 

 

 

 

-20°F SST

-29°C SST

No.

CFM

m3H

 

 

 

 

BTUH

Watts

 

 

 

 

 

GLC035

3,500

1,025

1

700

 

1,189

 

GLC040

4,000

1,170

1

700

 

1,189

 

GLC047

4,700

1,380

1

650

 

1,104

Inch

GLC065

6,500

1,900

2

1,400

 

2,379

GLC075

7,500

2,200

2

1,300

 

2,209

GLC090

9,000

2,640

2

1,300

 

2,209

Per

 

GLC120

12,000

3,520

3

2,100

 

3,568

6 Fins

GLC140

14,000

4,100

3

1,950

 

3,313

GLC160

16,000

4,690

4

2,600

 

4,418

 

GLC180

18,000

5,280

4

2,600

 

4,418

 

GLC200

20,000

5,860

5

3,250

 

5,522

 

GLC240

24,000

7,030

6

3,900

 

6,627

 

GLC280

28,000

8,200

6

3,900

 

6,627

 

GLC041

4,100

1,200

1

690

 

1,172

Inch

GLC068

6,800

2,000

2

1,380

 

2,345

GLC080

8,000

2,340

2

1,380

 

2,345

Per

GLC102

10,200

2,990

3

2,170

 

3,687

GLC136

13,600

3,990

4

2,760

 

4,690

Fins

 

GLC170

17,000

4,980

5

3,450

 

5,862

4

GLC204

20,400

5,980

6

4,140

 

7,035

 

 

 

GLC235

23,500

6,880

6

4,140

 

7,035

Model GLC Hot Gas Defrost 50 Hz

 

 

Capacity

 

Fan Data

 

 

Model

10°F TD

6°C TD

 

 

 

 

 

-20°F SST

-29°C SST

No.

CFM

m3H

 

 

 

 

BTUH

Watts

 

 

 

 

 

GLC035

3,325

974

1

630

 

1,070

 

GLC040

3,800

1,113

1

630

 

1,070

 

GLC047

4,465

1,308

1

586

 

995

Inch

GLC065

6,175

1,809

2

1,260

 

2,142

GLC075

7,125

2,087

2

1,170

 

1,989

 

 

Per

GLC090

8,550

2,504

2

1,170

 

1,989

GLC120

11,400

3,339

3

1,891

 

3,213

6 Fins

GLC140

1,950

3,313

3

1,756

 

2,984

GLC160

2,600

4,418

4

2,341

 

3,978

 

GLC180

2,600

4,418

4

2,341

 

3,978

 

GLC200

3,250

5,522

5

2,927

 

4,973

 

GLC240

3,900

6,627

6

3,512

 

5,967

 

GLC280

3,900

6,627

6

3,512

 

5,967

 

GLC041

690

1,172

1

621

 

1,056

Inch

GLC068

1,380

2,345

2

1,243

 

2,111

GLC080

1,380

2,345

2

1,243

 

2,111

Per

GLC102

2,170

3,687

3

1,954

 

3,320

GLC136

2,760

4,690

4

2,485

 

4,223

Fins

 

GLC170

3,450

5,862

5

3,107

 

5,279

4

 

 

 

 

 

 

 

GLC204

4,140

7,035

6

3,728

 

6,334

 

 

 

GLC235

4,140

7,035

6

3,728

 

6,334

For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will not see a reduction in performance due to the electronic

control of the motor)

Capacity Correction Factors For Electric and Hot Gas Defrost Units

Saturated Suction

+20

-10

-20

-30

Temperature °F

 

 

 

 

Saturated Suction

-7

-23

-29

-34

Temperature °C

 

 

 

 

Multiply Capacity

1.15

1.04

1.00

0.90

By

 

 

 

 

NOTE: When using the hot gas units with a hot gas loop drain pan on 0°F applications and below, an insulated drain pan is required.