ANÁLISIS DE AVERÍAS

La campana no suena:

Revise el disyuntor que va al transformador: Restaure el disyuntor si se ha disparado.

Restaure la campana: Presione el botón de restauración que está en la parte frontal de la base de la campana (vea la Figura 3).

Inspeccionar la campana: Desconectar el cable del terminal marcado "TRANS". Hacer que al- guien oprima el botón en la puerta delantera mientras usted toca brevemente el cable "TRANS" al terminal marcado "FRONT". Si el botón, cableado, y transformador están operando bien se obser- va una pequeña chispa. Repetir los pasos para el terminal "REAR" y el botón posterior. Reempla- zar la campana, si el cableado entre el transformador y el botón(es) está bien.

Inspeccionar el botón(es): Extraer la unidad sospechosa del marco de la puerta, desconectar el cable de los terminales y juntar los cables expuestos. Si la campana funciona, el botón es defec- tuoso. Reemplazar el botón.

Inspeccionar el transformador: Tocar brevemente los dos terminales de bajo voltaje con un des- tornillador. Si el transformador opera bien se observa una chispa pequeña. Reemplazar el transfor- mador si no se observa una chispa.

La campana suena pero no completa el tono:

Inspeccionar el diodo en el botón delantero: Verificar que el diodo está bien fijado al botón (vea la Figura 4). Si aún el tono no suena por completo, reemplace el diodo.

SERVICIO TÉCNICO

(No enviar los productos)

Si tiene algún problema por favor siga esta guía. Lo sentimos, pero no podemos con- testar preguntas en español por teléfono. Usted puede también escribir* a:

DESA Specialty Products™

P.O. Box 90004, Bowling Green, KY 42102-9004

*Si se llama al Servicio Técnico, por favor tener lista la siguiente información: Número de Modelo, Fecha de compra y Lugar de compra.

No hay piezas de servicio disponibles para este producto

598-1142-01

15

Page 15
Image 15
Heath Zenith 121AC, 122C, 125C installation instructions Análisis DE Averías, Servicio Técnico

121AC, 125C, 122C specifications

Heath Zenith has established a reputation for innovation and quality in the outdoor lighting and security market with its range of products designed to enhance safety and convenience around the home. Among their notable offerings are the Heath Zenith 122C, 125C, and 121AC, each boasting unique features and advanced technologies.

The Heath Zenith 122C is a motion-activated security light designed with both functionality and aesthetics in mind. This model features a powerful 180-degree motion sensor that detects movement up to 30 feet away. One of its standout technologies is the adjustable sensitivity feature, which allows users to customize the detection range according to their needs. Additionally, the 122C offers dual lights that provide excellent illumination for entryways, garages, and outdoor spaces, ensuring that any movement is clearly visible.

Similarly, the Heath Zenith 125C enhances outdoor security with a robust design and advanced features. This model is equipped with a 240-degree motion sensor, which provides a wider range of coverage compared to its counterpart. The 125C also includes a convenient test mode that makes it easy for users to adjust the positioning of the sensor and lights to achieve optimal performance. Users appreciate the weather-resistant casing that protects the light from environmental elements, ensuring durability and longevity.

The Heath Zenith 121AC light features a combination of innovation and ease of use. It stands out for its integrated dusk-to-dawn sensor, which automatically activates the light at sunset and turns it off at sunrise, providing hassle-free operation. This feature not only enhances convenience but also contributes to energy savings by ensuring the light is only on when needed. The 121AC is designed with LED technology, making it energy-efficient, providing bright illumination, and reducing maintenance costs due to the extended lifespan of LEDs.

All three models come with adjustable light timers that allow users to set how long the light stays on after being triggered. This ensures flexibility for various applications, whether for security purposes or general outdoor lighting. The Heath Zenith 122C, 125C, and 121AC lights exemplify the perfect blend of practical features and advanced technologies, making them excellent choices for homeowners looking to improve safety and illumination around their properties. With reliable performance and user-friendly features, these models reflect Heath Zenith's commitment to quality and innovation in outdoor lighting solutions.