Heath Zenith manual Operating Instructions & Parts Manual, 2LBL5, 2LBL6

Models: 2LBL6 2LBL5

1 4
Download 4 pages 45 Kb
Page 1
Image 1
Operating Instructions & Parts Manual

Operating Instructions & Parts Manual

2LBL5, 2LBL6

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply could result in personal injury and/or property damage! Save these instructions for future reference.

®Model 2LBL5: 150 Watt High Pressure Sodium Security Light

Model 2LBL6: 100 Watt Metal Halide Security Light

NOTE: All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of the system.

Lamp in Fixture Contains Mercury. Dispose According to Local, State, or Federal Laws.

2LBL5, 2LBL6 WARNING: Turn power off at the fuse or circuit breaker.

1.Select a location on a flat wall with structurally sound wood and from 10 to 25 feet from the ground. The wood should be at least one inch thick to safely secure the fixture.

2.Attach the cover plate using two large machine screws.

3.Using the mounting bracket as a template. Hold it at the desired mounting location (making sure the bottom is level), and mark four mounting holes. We suggest drilling 3/16" pilot holes for the lag screws.

4.Put the two top lag screws through their holes in the mounting bracket and hold them in place while you push the gasket onto these lag screws. Start these two screws into the two top pilot holes.

5.Start the other two lag screws, and then tighten all four screws.

6.Hang the fixture on the mounting bracket using the slot in the cover plate.

7.Twist the fixture wires to the supply wires. (black to black, white to white, and the bare fixture wire to the supply ground wire).

8.Make sure the wires do not get pinched, and swing the fixture up so the base fits tightly against the gasket. Push the pin through the hole at the top near the gasket, and into the mating loop in the mounting bracket. You may need to tap the pin to seat it all the way down.

9.Secure the fixture with the small machine screw going through the cover plate and into the mounting bracket.

10.Install lamp. Lamp rating must match the rating of the fixture. Model 2LBL5: 150 Watt high pressure sodium type S55 lamp. Model 2LBL6: 100 Watt metal halide type M90/O open rated lamp.

11.Hold the lens and wire cage up to the fixture and align the clips on the wire cage with the protrusions in the housing. Hook the clips over these protrusions and snap the clips closed to hold the lens and wire cage in place.

12.Loosen the screw in the center of the photocontrol socket two turns. Twist the socket so that the arrow points north. Note: There is a stop to prevent the socket from turning all the way around.

If you have trouble turning the socket, try turning it the other direction. Retighten the screw in the center of the socket.

13.Align the photocontrol (it will only plug-in one way). Plug it in and twist clockwise until it stops.

14.Caulk fixture mounting surface with silicone weather sealant

To test operation during daylight, cover the photocontrol with a small box. Turn on the power. Not all photocontrols are alike. Some may have a time delay of a few minutes, others will turn on as soon as power is applied. The light will take up to ten minutes to reach full brightness. Uncover the photocontrol and your unit will operate automatically—on at dusk, off at dawn.

Housing

Photocontrol

 

Model 2LBL6: 100 Watt Metal Halide Security Light Pin

Lag Screw

(4) Mounting

Bracket

Cover

LampPlate

Gasket

Lens

598-1318-01

HEA 013LPG-9272, LPG-9274 Printed in China

02/08

Page 1