Heath Zenith 5326 manual Test And Adjustment, Bottom of Sensor, Maximum Range, Coverage Angle

Models: 5326

1 20
Download 20 pages 17.49 Kb
Page 4
Image 4
TEST AND ADJUSTMENT
Clamp Screw
Ball Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the RANGE control to the medium position (halfway between MIN and MAX), DualBrite® to OFF, and the ON-TIME control to the TEST position.

MAX

 

 

 

 

B

O

ON - TIME

DUAL BRITE

 

 

O

 

 

 

S

 

 

 

MIN

T

 

 

 

TEST 1 5 2 0

OFF 3 6

DUSK TO

RANGE

 

MINUTES

HOUR

DAWN

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

240°

8 ft.

(2.4 m)

70 ft.

100 ft.

 

(21 m)

(30.5 m)

 

 

Boosted

 

Maximum Range

Maximum

Coverage Angle

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

MotionMotion

 

Sensor

Least Sensitive

Most Sensitive

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (25 mm) away from the bulbs.

Adjust the RANGE as needed.

RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes).

Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).

❒Turn on the circuit breaker and light switch. WARNING - Risk of fire. Do not aim the bulbs at a combustible surface within 3 ft. (1 m).