TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.❒Set the
NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.
10 TEST
❒Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.
❒Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (2.5 cm) away from the lamps.
❒Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.
❒Set the
Clamp
Screw
Ball
Joint
Aim SensorDown for Short
Coverage
Aim Sensor
Higher for Long
CoverageBottom of Sensor
Avoid aiming the control at:•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
8 ft. | 110° |
| |
(2.4 m) |
|
50 ft. |
|
(15.2 m) |
|
Maximum Range | Maximum |
| Coverage Angle |
The detector is most sensitive to motion across its field of view.
Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . Up to 50 ft. (15.2 m) [varies with surrounding temperature].
Sensing Angle. . . . Up to 110°
Electrical Load. . . . Up to 300 Watt Maximum In- candescent [Up to 150 Watt maximum each lamp holder.]
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . 10 minutes Range . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
Motion
Motion
| Sensor |
Least Sensitive | Most Sensitive |