Heath Zenith P6036 manual Installation, Wire the Light Control, Red Sensor Wire to, White to White

Models: P6036

1 4
Download 4 pages 16.43 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of elec- trical shock.

For eave mount only:

Swing the sensor head towards the clamp

screw.Controls Clamp Screw Wire the Light Control

Rotate the sensor head clockwise 180° so the controls face down.

Controls

Red Sensor Wire to Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

These instructions show the sensor wired to flood- lamps.The white sensor wire is neutral.The black sensor wire is hot. The red wire is the switched "hot" wire. The lighting load (500 W, 4.2A max) is placed across the white and red wires.

Wire the Light Control

White to White WARNING: Turn power off at the fuse or circuit breaker.

Remove the existing light fixture, if present.

After screwing the sensor into the wall plate, connect the junction box wires to the Light Control wires by twisting together and securing with wire connectors.

 

 

Red Sensor Wire to

White to White

 

Black Lamp Wire

 

 

 

Junction

Box

Lamp Holders

Black to Black

Optional: Connect additional load across the white and red wires. Total lighting load including lampheads on fixture must not exceed 500W (4.2A).

Mount the Light

Followtheinstructionsthatcamewithyourlightfix- ture for mounting and adjusting the light fixture.

Keep regular PAR-38 lamps at least 1" (25 mm) from the sensor. Halogen lamps should be kept at least 2" (51 mm) from the sensor.

--

598-1280-00

Page 2
Image 2
Heath Zenith P6036 manual Installation, Wire the Light Control, Red Sensor Wire to, White to White, Black Lamp Wire