TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute calibration period before it will detect motion. When first turned on, wait 1 1/2 minutes.
❒Turn the RANGE control to the mid position and the
❒ Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.
❒ Walk through the cover- age area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected). Move the sensor head up, down,
10 5 1 TEST
RANGE
MIN MAX
or sideways to change the coverage area. Keep the sensoratleast1"(2.5cm) away from the lamps.
❒ Adjust the RANGE as needed. RANGE set too
Bottom of Sensor
Avoid aiming the control at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
8 ft. | 180° | |
(2.4m) | ||
| ||
70 ft. |
| |
(21m) |
| |
Maximum Range | Maximum | |
| Coverage Angle |
Thesensorislesssensitivetomotiondirectlytowards it, most sensitive to motion across its field of view.
MotionMotion
| Sensor |
Least Sensitive | Most Sensitive |
high may increase false triggering.
❒ Secure the sensor head by tightening the clamp
screw. Do not overtighten the screw.
❒Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).
Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].
Sensing Angle. . . . . Up to 180°
Electrical Load. . . . . Upto500Watt(4.2A)Maximum Incandescent [Up to 250 Watt maximum each lamp holder.]
Power Requirements. . 120 VAC, 60 Hz
Operating Modes. . . . TEST, AUTO, and MANUAL MODE
Time Delay . . . . . . 1, 5, 10 minutes Range . . . . . . . . Adjustable