Heath Zenith PF-4197-WH, PF-4192-WH, PF-4192-BK warranty Specifications, Troubleshooting Guide

Models: PF-4192-BK PF-4197-WH PF-4192-WH

1 24
Download 24 pages 15.25 Kb
Page 7
Image 7

SPECIFICATIONS

Range . . . . . . Up to 30 ft. (9.1 m) [varies with surrounding temperature].

Sensing Angle. . . Up to 180°

Electrical Load. . . See rating on fixture for maximum wattage.

Sensor Capacity . . Up to 360 Watt (3.0 A.) Maximum Tungsten Incandescent

Power

Requirements . . . 120 VAC, 60 Hz Operating Modes. . TEST, AUTO, and

MANUAL MODE Time Delay . . . . 1, 5, 10 minutes DualBrite® timer . . Off, 3, 6 hrs, Dusk-to-

Dawn

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorpo- rate new features in products previously sold.

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

 

 

 

 

 

 

Light will not

1.

Light switch is turned off.

come on.

2. Bulb is loose or burned out.

 

3.

Fuse is blown or circuit breaker

 

 

is turned off.

 

4.

Daylight turn-off is in effect

 

 

(recheck after dark).

 

5.

Incorrect circuit wiring, if this is

 

 

a new installation.

 

 

Light comes on

1. Light control may be installed

in daylight.

 

in a relatively dark location.

 

2.

Light control is in Test. (Set

 

 

control switch to an ON-TIME

 

 

position.)

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

 

 

Light comes

1. Light control may be sensing

on for no ap-

 

small animals or automobile

parent reason.

 

traffic (Reduce sensitivity).

 

 

Light stays on

1. The sensor is pointed toward

continuously.

 

a heat source like an air vent,

 

 

dryer vent, or brightly-painted

 

 

heat-reflective surface.(Reduce

 

 

sensitivity.)

 

2.

Light control is in Manual Mode.

 

 

(Switch to Auto.)

 

3.

Light control is in DualBrite®

 

 

mode.

 

4.

Sensitivity is set too high. (Re-

 

 

duce sensitivity.)

 

 

 

Light flashes

1.

Light control is in the Test

on and off.

 

mode and war ming up.

 

 

(Flashing is normal under these

 

 

conditions).

 

 

 

598-1167-05

Page 7
Image 7