Heath Zenith PF-4300-BK warranty Specifications, Troubleshooting Guide, Technical Service

Models: PF-4300-BK

1 24
Download 24 pages 14.09 Kb
Page 7
Image 7

SPECIFICATIONS

Range

Up to 30 ft. (9.1 m) [varies

 

with surrounding tem-

 

perature].

Sensing Angle

360°

Electrical Load

Up to 100 Watt Maximum

 

Tungsten Incandescent

 

(Up to 25 Watt Maximum

 

each lamp holder).

Bulb Type

Candelabra Base, Type

 

“B”, 25 Watt Maximum

Sensor Capacity

Up to 200 Watt (1.7 A.)

 

Maximum Tungsten In-

 

candescent

Power Requirements

120 VAC, 60 Hz

Operating Modes

TEST, AUTO/ACCENT,

 

and MANUAL MODE

ON-Timer

1, 5, 10 minutes

DualBrite® Timer

Off, 3, 6 Hrs, Dusk-to-

 

Dawn

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

 

 

 

Light will not

1.

Light switch is turned off.

come on.

2.

Bulbs are loose or burned out.

 

3.

Fuse is blown or circuit breaker

 

 

is turned off.

 

4.

Daylight turn-off is in effect (re-

 

 

check after dark).

 

5.

Incorrect circuit wiring, if this is

 

 

a new installation.

 

 

 

Light comes on

1.

Sensor may be installed in a

in daylight.

 

relatively dark location.

 

2.

Sensor is in Test. (Set control

 

 

switch to an ON-TIME position.)

 

 

 

Light comes on

1.

Sensor may be sensing small

for no apparent

 

animals or automobile traffic.

reason.

 

(Reduce sensitivity.)

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

 

Light stays on

1.

There is a heat source like an

continuously.

 

air vent, dryer vent, or brightly-

 

 

painted, heat-reflective surface in

 

 

the coverage area. (Install shield

 

 

on sensor in the direction of heat

 

 

source.)

 

2.

Light control is in Manual Mode.

 

 

(Switch to Auto.)

 

3.

Light control is in DualBrite®

 

 

mode.

 

4.

Sensitivity is set too high.(Reduce

 

 

sensitivity.)

 

 

Light flashes on

1. Sensor is in the Test mode.(While

and off.

 

in TEST mode, light only stays on

 

 

for 5 seconds.)

 

 

 

Light does not

1.

Nearby large, light-colored objects

stay on in Man-

 

reflecting light may trigger the

ual mode.

 

shut-off feature.Do not point other

 

 

lights at the sensor.

 

 

 

Technical Service

Please call 1-800-858-8501 (English speaking only) for assistance before returning

product to store.

If you experience a problem, follow this guide.You may also want to visit our Web site at: www.hzsupport. com. If the problem persists, call* for assistance at 1-800-858-8501(English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to:

HeathCo LLC

P.O. Box 90004, Bowling Green, KY 42102-9004

ATTN: Technical Service

*If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product

598-1169-05