SPECIFICATIONS
Range | Up to 30 ft. (9.1 m) [varies |
| with surrounding tem- |
| perature]. |
Sensing Angle | 360° |
Electrical Load | Up to 100 Watt Maximum |
| Tungsten Incandescent |
| (Up to 25 Watt Maximum |
| each lamp holder). |
Bulb Type | Candelabra Base, Type |
| “B”, 25 Watt Maximum |
Sensor Capacity | Up to 200 Watt (1.7 A.) |
| Maximum Tungsten In- |
| candescent |
Power Requirements | 120 VAC, 60 Hz |
Operating Modes | TEST, AUTO/ACCENT, |
| and MANUAL MODE |
1, 5, 10 minutes | |
DualBrite® Timer | Off, 3, 6 Hrs, |
| Dawn |
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM | POSSIBLE CAUSE | |
|
|
|
Light will not | 1. | Light switch is turned off. |
come on. | 2. | Bulbs are loose or burned out. |
| 3. | Fuse is blown or circuit breaker |
|
| is turned off. |
| 4. | Daylight |
|
| check after dark). |
| 5. | Incorrect circuit wiring, if this is |
|
| a new installation. |
|
|
|
Light comes on | 1. | Sensor may be installed in a |
in daylight. |
| relatively dark location. |
| 2. | Sensor is in Test. (Set control |
|
| switch to an |
|
|
|
Light comes on | 1. | Sensor may be sensing small |
for no apparent |
| animals or automobile traffic. |
reason. |
| (Reduce sensitivity.) |
|
|
|
SYMPTOM | POSSIBLE CAUSE | |
|
|
|
Light stays on | 1. | There is a heat source like an |
continuously. |
| air vent, dryer vent, or brightly- |
|
| painted, |
|
| the coverage area. (Install shield |
|
| on sensor in the direction of heat |
|
| source.) |
| 2. | Light control is in Manual Mode. |
|
| (Switch to Auto.) |
| 3. | Light control is in DualBrite® |
|
| mode. |
| 4. | Sensitivity is set too high.(Reduce |
|
| sensitivity.) |
|
| |
Light flashes on | 1. Sensor is in the Test mode.(While | |
and off. |
| in TEST mode, light only stays on |
|
| for 5 seconds.) |
|
|
|
Light does not | 1. | Nearby large, |
stay on in Man- |
| reflecting light may trigger the |
ual mode. |
| |
|
| lights at the sensor. |
|
|
|
Technical Service
Please call
product to store.
If you experience a problem, follow this guide.You may also want to visit our Web site at: www.hzsupport. com. If the problem persists, call* for assistance at
HeathCo LLC
P.O. Box 90004, Bowling Green, KY
ATTN: Technical Service
*If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.