Mode Switching Summary

TEST Move ON-TIME Switch to 1, 5, or 10 minutes

 

AUTO

 

 

 

 

Flip light switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off for one second

 

 

 

 

 

 

 

 

then back on*

MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the cali- bration time the control will be in the AUTO mode.

INSTALLATION

Caution: Risk of fire.This fixture is designed for wall mounting only. DO NOT install on a ceiling or soffit.

For easy installation, select an existing light operated by a wall switch for replacement.

For best performance, mount the fixture about 8 feet (2.4 m) above the ground. NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

Attach the lamp arm to the backplate arm and secure with the long bolt.

Note:When tightening the arm screw, pull on the wires to make sure the wires are not pinched by the joint.

Drill out the holes if needed to mount the backplate to the junction box.

Wire the Light Control

WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fixture.

The S-hook can be used to hold the fixture while wiring. The small end of the hook can be inserted into a hole in the junction box. The large end goes around the “neck” of the fixture.

Route the light control’s wires through the large hole in the gasket.

Twist the junction box wires and fixture wires together as shown. Secure with a wire connector.

Black to Black

Cover Plate

Gasket

White to White

Junction box ground wire to green ground wire on fixture.