TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the RANGE control to the medium position (halfway between MIN and MAX),DualBrite® OFF, and the ON-TIME control to the TEST position.

MAX

 

ON-TIME

DUAL BRITE™

 

O

 

B

 

 

 

O

 

 

 

S

 

 

 

T

 

 

MIN

TEST 1 5 20

OFF 3 6 DUSK TO

RANGE

 

MINUTES

HOUR DAWN

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detect- ed).Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (25 mm) away from the bulbs.

AdjusttheRANGEasneeded. RANGE set too high may increase false triggering.

Secure the sensor head's aim by tightening the clamp screw. Do not overtighten the

Clamp

❒Turn on the circuit breaker and light switch. Screw

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Bottom of Sensor

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

240°

15 ft.

 

 

(4.6 m)

DualZone

 

DualZone

70 ft. 100 ft.

 

(21 m) (30.5 m)

 

 

Boosted

Maximum

 

 

Maximum Range

Coverage Angle

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

MotionMotion

DualZone

Sensor

DualZone

 

 

Least Sensitive

 

Most Sensitive

screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes).

Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).

ClampWARNING - Risk of fire. Do not aim the bulbs at a combustible surface within 3 ft. (1 m).

NOTE: DualZone™ is a new zone of detection which was added as an option to select Heath®/Zenith motion sensing products. This feature adds a zone of detec- tion under the motion sensor. DualZone™ requires no additional adjustment and operates in conjuction with the forward-looking sensor.

SPECIFICATIONS

Horizontal Range. .

. Up to 70 ft. (21 m); 100 ft.

 

(30.5 m) with Range Boost.

 

[varies with surrounding

 

temperature]

Vertical Range. . .

. Up to 15 ft. (4.6 m)

Sensing Angle. . .

. Up to 240° horizontal. Up to 80°

 

Vertical

Electrical Load. . .

. Up to 500 Watts Maximum In-

 

candescent

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

 

MODE

Time Delay . . . .

. 1, 5, 20 minutes

DualBrite® Timer. .

. Off, 3, 6 hours, Dusk-to-Dawn

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.