Mode Switching Summary
TEST Move
| AUTO |
|
|
|
| Flip light switch | ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| off for one second |
|
|
|
|
|
|
|
| then back on* |
MANUAL MODE |
|
| ||||||
|
|
| ||||||
|
|
*If you get confused while switching modes, turn the power off for one minute, then back on. After the cali- bration time the control will be in the AUTO mode.
INSTALLATION
For easy installation, select an existing light operated by a wall switch for replacement.
For best performance, mount the fixture about 8 feet (2.4 m) above the ground. NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.
❒ Drill the holes needed to mount the backplate to the junction box.
Eave Mount | Wall Mount |
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.
For eave mount only:
❒Swing the sensor head towards the clamp screw joint.
Clamp Screw
Controls
❒Then rotate the sensor head clockwise 180° so the controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.