Heath Zenith SL-4190 manual Testing, Specifications, Maximum Range, Avoid aiming the control at

Models: SL-4190

1 20
Download 20 pages 44.48 Kb
Page 5
Image 5
TESTING

TESTING

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up pe- riod before it will detect motion.When first turned on, wait 1 1/2 minutes.

Switch the on-time to TEST position and DUALBRITE® switch to the OFF position.

 

 

 

 

 

 

TEST 1 5 10 MIN

OFF 3 6 DUSK TO

 

ON-TIME

 

HOUR DAWN

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air condition- ers. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

6 ft.

180°

 

(1.8 m)

 

30ft.

(9.1 m)

Maximum Range

Maximum

 

Coverage Angle

The detector is less sensitive to motion directly towards it and more sensitive to across motion.

Motion

Motion

 

 

Sensor

Least Sensitive
Most Sensitive

Walk through the coverage area noting where you are when the lights turn on.

If you need to change the sensitivity, temporarily remove the fixture and make the adjustment. Too much sensitivity may increase false triggering.

Set the amount of TIME you want the light to stay on after motion is detected. (1, 5, or 10 minutes).

Set the amount of time after dusk you want the lights on accent level.

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 30 ft. (9.1 m) [varies with s u r r o u n d i n g temperature].

Sensing Angle . . . . . . Up to 180° Electrical Load. . . . . . S e e r a t i n g o n

fixture for maximum wattage.

Sensor Capacity . . . . Up to 360 Watt (3.0 A.) Maximum

Power Requirements . 120 VAC, 60 Hz Operating Modes . . . . TEST, AUTO and

MANUAL MODE Time Delay . . . . . . . . 1, 5, 10 minutes DUALBRITE® timer . . . . 3, 6 hrs, Dusk-to-

Dawn

DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

595-5628-07

5

Page 5
Image 5
Heath Zenith SL-4190 Testing, Specifications, Maximum Range, Turn on the circuit breaker and light switch, Coverage Angle