TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period be- fore it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes.
❒Turn the RANGE control to the mid position and the
RANGE
ON-TIME
10 5 1 TEST | MIN | MAX |
|
Bottom of Sensor
Avoid aiming the sensor at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
180°
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range | Maximum |
| Coverage Angle |
The detector is less sensitive to motion directly towards it.
❒ Loosen the clamp screw in the | Clamp |
sensor ball joint and gently | Screw |
rotate the sensor. |
|
❒ Walk through the coverage | Ball |
area noting where you are | Joint |
when the lights turn on. Move |
|
the sensor head up, down, |
|
or sideways to change the | Aim Sensor |
coverage area. | |
❒ Adjust the RANGE as needed. | Down for Short |
RANGE set too high may | Coverage |
increase false triggering. |
|
❒Secure the sensor head’s
aim by tightening the clamp screw. Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay on after
motion is detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature]
Sensing Angle. . . . Up to 180°
Electrical Load. . . . Up to 500 Watt Maximum Incandescent
Power Requirements. . 120 VAC, 60 Hz
Operating Modes. . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . 1, 5, 10 minutes Replacement lamp. . . T 500W (or less) halogen 120
VAC
HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
MotionMotion
| Sensor |
Least Sensitive | Most Sensitive |