Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

ON-TIME

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

MIN MAX

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

8 ft.

150°

 

(2.4 m)

 

70 ft.

 

(21 m)

 

Maximum Range

Maximum

 

Coverage Angle

The detector is most sensitive to motion across its field of view.

Loosen the clamp screw in

Clamp

the sensor ball joint and gen-

Screw

tly rotate the sensor.

 

Walk through the coverage

Ball

area noting where you are

Joint

when the lights turn on (also,

 

the LED will flash several times

 

when motion is detected).

 

Move the sensor head up,

 

down, or sideways to change

Aim Sensor

the coverage area. Keep the

Down for Short

sensor at least 1" (2.5 cm)

Coverage

away from the lamps.

 

Adjust the RANGE as needed.

RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle . . . . . . Up to 150°

Electrical Load . . . . . . Up to 300 Watt Maximum In- candescent [Up to 150 Watt maximum each lamp holder.]

Power Requirements . 120 VAC, 60 Hz

Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1 , 5, 10 minutes

DESA Specialty Products™ reserves the right to dis- continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

Motion

Motion

Sensor

Least Sensitive

Most Sensitive

595-5766-03

3

Page 3
Image 3
Heath Zenith SL-5411 manual Test and Adjustment, Specifications, Bottom of Sensor