INSTALLATION

 

 

INSTALLATION

Mounting

For easy installation, select an existing light with a wall

Strap

switch for replacement.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black to Black

White to White

Rubber

Plug

Eave Mount

Wall Mount

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp screw

joint.Controls ClampBlack to Black

Screw

23456789012345678

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Controls Eave Mount

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

WIRE THE LIGHT CONTROL.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Install the mounting strap as shown using two screws that fit your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Route the Light Control’s wires through the large gasket holes.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

Mounting

Bolt

Gasket

Junction box ground wire to green ground screw on fixture.

MOUNT THE LIGHT CONTROL.

Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt.

Align the three slots in the decorative shell with the lamp holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell.

Shell Slot

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

To avoid water damage and electrical shock, keep lamp holders 30° below horizontal.

 

Keep lamps at least

 

1" (2.5 cm) from the

 

sensor. Do not al-

Lock Nut

low the lamps to

block the lens.

 

Lens

 

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.