TROUBLESHOOTING GUIDE

SYMPTOM

 

POSSIBLE CAUSE

 

 

 

 

 

Lights will not come

1. Light switch is turned off.

on.

 

2. Flood light

is

loose or

 

 

 

burned out.

 

 

 

 

3.

Fuse is blown or circuit breaker is

 

 

 

turned off.

 

 

 

 

4.

Daylight turn-off is in effect (re-

 

 

 

check after dark).

 

 

 

5.

Incorrect circuit wiring, if this is a

 

 

 

new installation.

 

 

 

6.

Re-aim the sensor to cover de-

 

 

 

sired area.

 

 

Lights come

on

1. Light Control may be installed in

in daylight.

 

 

a relatively dark location.

 

 

2.

Light Control is in Test.

 

 

 

(Set control switch to an

 

 

 

ON-TIME position).

 

 

 

 

 

Lights come on for

1. Light Control

may

be sensing

no apparent

rea-

 

small animals or automobile traf-

son.

 

 

fic (re-aim sensor).

 

 

 

2.

Range is set too high .

 

 

 

(Reduce Range).

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

 

 

Lights stay on

1. A flood lamp is positioned too close to

continuously.

the sensor or pointed at nearby ob-

 

jects that cause heat to trigger the

 

sensor. (Reposition the lamp away

 

from the sensor or nearby objects).

 

2. Light Control is pointed toward a heat

 

source like an air vent, dryer vent, or

 

brightly-painted heat-reflective sur-

 

face. (Reposition sensor).

 

3. Light Control is in Manual Mode.

 

(Switch to Auto.)

 

 

Lights flash on

1. Heat or light from the lamps may be

and off.

turning the Light Control on and off.

 

(Reposition the lamps away from the

 

sensor).

 

2. Heat being reflected from other ob-

 

jects may be affecting the sensor.

 

(Reposition sensor).

 

3. Light Control is in the Test mode and

 

warming up. (Flashing is normal un-

 

der these conditions).

 

4. Light may be leaking through the

 

floodlampreflectors.(Replacethelamps

 

with new high quality PAR 38 lamps).

 

 

TECHNICAL SERVICE

(Do Not Send Products)

If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem persists, call* for assistance at 1-800-858-8501,7:30 AM to 4:30 PM CST (M-F). You may also write* to: DESA Specialty Products™

P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service Specialty Products

*If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product.

To obtain a refund or replacement, return the Product to the place of purchase.