Test and Adjustment

Turn on the circuit breaker and light switch.

Monitor light control to verify that the lights come on at night and turn off during the day.

Adjust bulb holders as needed.

WARNING: Risk of fire. Do not aim the bulbs at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Electrical Load

Up to 300 Watt Maximum

 

Incandescent [Up to 150 Watt

 

maximum each bulb holder.]

Power Requirements...

120 VAC, 60 Hz

Operating Modes

Dusk to Dawn

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

SOLUTION

 

 

 

 

 

Lights will not come on.

1.

Light switch is turned off.

1.

Turn light switch on.

 

2.

Floodlight is loose or burned out.

2.

Check floodlight and replace if

 

 

 

 

burned out.

 

3.

Fuse is blown or circuit breaker is

3.

Replace fuse or turn circuit breaker

 

 

turned off.

 

on.

 

4.

Daylight turn-off is in effect.

4.

Recheck after dark.

 

5.

Incorrect circuit wiring, if this is a

5.

Verify wiring is correct.

 

 

new installation.

 

 

 

 

 

Lights stay on continuously.

Light control is mounted in a dark

Relocate light control to an area that

 

location.

receives more light.

 

 

 

 

 

Lights flash on and off.

1.

Light may be leaking through the

1.

Replace the bulbs with new high

 

 

floodlamp reflectors.

 

quality PAR 38 bulbs.

 

2.

Light control may be sensing shad-

2.

Relocate light control to an area

 

 

ows.

 

away from shadows.

 

 

 

 

 

598-1299-01