Test and Adjustment
Turn on the circuit breaker and light switch.
Monitor light control to verify that the lights come on at night and turn off during the day.
Adjust bulb holders as needed.
WARNING: Risk of fire. Do not aim the bulbs at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Electrical Load | Up to 300 Watt Maximum |
| Incandescent [Up to 150 Watt |
| maximum each bulb holder.] |
Power Requirements... | 120 VAC, 60 Hz |
Operating Modes | Dusk to Dawn |
HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM | POSSIBLE CAUSE | SOLUTION | ||
|
|
|
|
|
Lights will not come on. | 1. | Light switch is turned off. | 1. | Turn light switch on. |
| 2. | Floodlight is loose or burned out. | 2. | Check floodlight and replace if |
|
|
|
| burned out. |
| 3. | Fuse is blown or circuit breaker is | 3. | Replace fuse or turn circuit breaker |
|
| turned off. |
| on. |
| 4. | Daylight | 4. | Recheck after dark. |
| 5. | Incorrect circuit wiring, if this is a | 5. | Verify wiring is correct. |
|
| new installation. |
|
|
|
|
| ||
Lights stay on continuously. | Light control is mounted in a dark | Relocate light control to an area that | ||
| location. | receives more light. | ||
|
|
|
|
|
Lights flash on and off. | 1. | Light may be leaking through the | 1. | Replace the bulbs with new high |
|
| floodlamp reflectors. |
| quality PAR 38 bulbs. |
| 2. | Light control may be sensing shad- | 2. | Relocate light control to an area |
|
| ows. |
| away from shadows. |
|
|
|
|
|