Wire the Light Control

Remove the existing light fixture.

Install mounting strap to junction box using screws appropriate for your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Thread all fixture wires through the large holes in the gasket as shown.

Connect the junction box wires to the light fixture wires as shown. Twist together and secure with wire connectors.

Mount the Light Control

Place the mounting bolt through the front of the junction box cover. Push the small gasket hole over the mounting screw.

Make sure the wire connectors and wires are inside the junction box. Align the mounting screw with the center hole in the mounting strap.Secure the fixture to the mounting strap.

Push the rubber plug over the mounting screw.

Mounting

Strap

White to

White

Black to

Black

Gasket

Rubber

Plug

Mounting

Bolt

Keep bulbs at least 1" (25 mm) from the sensor.

Push the rubber plug firmly into place.

If not installed on a weatherproof box, caulk the wall plate and mounting surface with silicone

Adjust the bulb holders by loosening the lock nuts but do not rotate the bulb holders more than 180° from the factory setting.

Connect any fixture ground wire(s) and the cover plate ground screw to the junction box ground wire.

598-1293-03

Page 3
Image 3
Heath Zenith UT-5512-BZ, UT-5512-WH manual Wire the Light Control, Mount the Light Control, White to Black to