![](/images/backgrounds/279380/bg9.png)
-9-
598-1290-02
Test and AdjustmentNOTES: When first turned on wait about 1 1/2
minutes for the circuitry to calibrate.
Testing with Range Boost on during day-
light may result in abnormal operation.
Sensor Bottom
Do not aim the sensor at:
• Objects that change temperature rapidly, such
as heating vents and air conditioners, to help
avoid false triggering.
• Where pets or traffic may trigger the con-
trol.
• Nearby large, light-colored objects reflecting
light may trigger the shut-off feature. Do not
point other lights at the sensor.
❒ Turn on the circu it breake r a nd light
switch.
❒ Open the control access cover (on bottom of unit)
by pulling down on the tab of the metal door.
❒ Turn the Range control to the center of its
adjustment and the ON-TIME to TEST posi-
tion.
B
O
O
S
T
MIN
TEST 1 5 20
RANGE
MAX
ON-TIME