8
Installation
A
b
C
d
minimum Clearances To Combustible materials
Sidewall To Appliance A 6” (152 mm) mur latéral à l’Appareil
backwall To Appliance b 6” (152 mm) mur Arrière à l’Appareil
Stove Top To Ceiling C 16” (406 mm) haut du Poêle au Plafond
Stove Front To Combustibles d 48” (1219 mm) des Combustibles au devant du Poêle
Combustibles To Pellet vent 3” (76 mm) matériaux Combustibles au Conduit de Fumée
minimum Alcove height 72” (1829 mm) hauteur de l’Alcôve
minimum Alcove width 48” (1219 mm) largeur de l’Alcôve
minimum Alcove depth 60” (1524 mm) Profondeur de l’Alcôve
wArNINg! rISk OF FIrE! Hearth & Home Technologies disclaims any responsibility for, and the warranty
and agency listing will be voided by the following actions:
dO NOT:
Install or operate a damaged appliance
Modify the appliance
Install other than as instructed by Hearth & Home Technologies
Operate the appliance without fully assembling all components
Overre the appliance
Install any component or part not approved by Hearth & Home Technologies
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage.
For assistance or additional information, consult a qualied installer, service agency or your dealer.