11
5 Operation

Operation

• Place the suction hose or suction arm at the workplace.
• Connect power plug.
• Switch on the unit.

Shutdown

• Switch off the unit.
• Disconnect the power cord.

Returning to Operation

• Check, if the suction hose is at the right place.
• Connect the power cord.
• Switch on the unit.
6 Cleaning and Maintenance 6.1 General Instructions
The combination of pre-filter and activated carbon guarantees a high filtration efficiency
of unhealthy gases, vapors and fumes. The large surface area and small particle size of
the actuated carbon maximizes absorption of polluted air.
The Filter Trolley 97612 is equipped with the filter indicator 2. This LED only indicates, if
the penetrability of the filter is worn. Then it is clogged and needs to be replaced.
The indication is not being laid out to record the chemical absorption of the activated
carbon filter. The absorption depends on the concentration of gases, vapors and fumes
at the workplace.
LED lights green: Filter is all right.
LED lights red: Filter is clogged - replacement necessary Replace the whole
filter.

Disposal

There are two possibilities to dispose the filter:
1. The filter has to be disposed according to the valid regional regulations.
2. A replacement filter is available, order code no. see section 8.1. For the replacement
procedure call your local Henkel Loctite representative.
6.2 Changing the Filter
• Shutdown the unit, see Section 5.
• Disconnect power plug.
Open the 3 snap locks.
• Remove the clogged or worn filter.
• Insert the new one.
Close the 3 snap locks.
• Return to operation, see Section 5.