Herrmidifier Co 707U-UK specifications Humidistat installation, Dedicatedwiring connection

Models: 707U 707U-UK

1 16
Download 16 pages 39.54 Kb
Page 12
Image 12
-Dedicated wiring connection

Electrical installation

Wiring diagram for humidifier installation - Free standing installation - (707U only)

-Dedicated wiring connection

I n p u t P o w e r

Humidistat installation

Humidistat:

1.Locate the humidistat in the living area (see location of humidifier diagram on page 4), making sure that it is at least five (5) feet from a supply register (duct mounted installation) or discharge nozzle (free standing installation).

2.The humidistat should be installed four and a half (4 1/2) feet above the floor, out of the direct sun and not subject to damage from traffic within the room.

3.If you would like the ability to cut off the electricity to the humidifier for maintenance, a throw -switch may be installed.

4.Turn the humidistat to the highest level (past 60%) and the humidifier should begin to run. The humidifier should stop when the humidistat is turned off.

5.Set the furnace controls and humidistat for the desired conditions (30-40% RH is recommended). Operation of this unit is automatic.

6.If condensation occurs on single pane windows, lower the humidistat setting until the condensation has disappeared.

NOTE: It may take several days for the humidity level in your home

to reach comfortable levels.

11