Herrmidifier Co 707U-UK Physical installation, Ferrule Compression Nut 1/4 Copper Tubing

Models: 707U 707U-UK

1 16
Download 16 pages 39.54 Kb
Page 10
Image 10
Ferrule

Physical installation

Final installation steps for all mounting locations

Install the saddle valve on the nearest cold water supply pipe (see the instructions on the package). If applicable, connect the saddle valve upstream of any type of water softener.

After the saddle valve has been installed and 1/4” copper tubing fitted to the valve, but before attaching the copper tubing to the float and valve assembly, turn the saddle valve to the open position and discharge the water into a bucket or pan. This will allow the water to void the line of any debris that may have accumulated during the installation process.

Attach the 1/4” copper tubing to the float and valve assembly with the ferrule and compression nut (provided).

Caution: The float and valve assembly must not turn when tightening the copper tubing compression fittings to the humidifier water reservoir pan fitting.

Turn the water supply on at the saddle valve.

Check the water level in the water reservoir pan to ensure it is 1-1 1/2” deep.

IMPORTANT:

In installations where accidental overflow could cause water damage, connect a drain hose from the humidifier water reservoir pan overflow tube to a drain. Do NOT use a soldered joint because the overflow tube will become heated and warp the water reservoir pan.

Ferrule

Saddle ValveCompression NutHumidifier Water

1/4" Copper Tubing

Saddle Valve

NOTE:

The following items are located in the bag identified:

“707 SM/STD Hardware Kit”:

Saddle valve assembly

Humidifier Water

Resivoir Pan

9

Page 10
Image 10
Herrmidifier Co 707U-UK specifications Physical installation, Ferrule Compression Nut 1/4 Copper Tubing, Saddle Valve