11. Function setting and changes
BE-IR20 / 21 14
11-4 Changes to fixed shutter mode
The fixed shutter mode can be changed by replacing the chip parts indicated below.
Mode R259 R260 R261 R262 R263 R264 R265 R266 R267 R268 R269
Normal mode 0Ω0ΩAbsent 0ΩAbsent 6800 10k 27k 10k 10k 27k
Auto electronic
shutter mode Remove Remove Absent 0ΩAbsent
EIA
1/100
CCIR
1/120
Remove 0Ω0ΩRemove Absent 0Ω0ΩRemove 0Ω0ΩRemove
1/250 Remove Remove 0Ω
1/500 Absent Remove 0Ω0Ω0ΩRemove
1/1000 Remove Remove 0Ω
1/2000 0ΩRemove Absent Remove Remove 0Ω0Ω0ΩRemove
1/5000 0ΩRemove Remove 0Ω
1/10000 Absent Remove 0Ω0Ω0Ω0ΩRemove
Fixed shutter mode
1/100000 0ΩRemove Remove 0Ω
R259 , R260 : 0Ω Part code RME2068
Description ERJ2GE0R00X
Others : 0Ω Part code RME1784
Description ERJ3GEYJ0R00V
(Main board side A) (Main board side B)Location of chip resistorsFactory
setting