Hitachi 222104 important safety instructions Performance Curves, Fluid FLOW--gpm lpm

Models: 222104

1 16
Download 16 pages 12.88 Kb
Page 15
Image 15

Performance Curves

Fluid

 

 

 

 

 

Air

Outlet Pressure,

KEY black curves=fluid outlet pressure

psi

Consumption

 

gray curves=air consumption

(MPa, bar)

 

scfm

150

 

 

 

 

 

 

(m#/min)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1.0, 10.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

125

 

 

 

D

 

10

 

 

 

 

 

 

 

 

 

 

 

(0.85, 8.5)

 

 

 

 

 

 

(0.280)

A40 psi (0.28 MPa, 2.8 bar) air pressure

B70 psi (0.48 MPa, 4.8 bar) air pressure

C100 psi (0.7 MPa, 7 bar) air pressure

D150 psi (1.0 MPa, 10.4 bar) air pressure

100

 

 

 

 

8

(0.7, 7)

 

 

 

 

(0.224)

 

 

C

 

 

 

75

 

 

 

 

6

(0.51, 5.1)

 

 

 

 

(0.168)

 

 

D

 

 

 

50

B

 

 

 

4

 

 

 

 

(0.34, 3.4)

 

 

C

 

(0.112)

 

 

 

B

 

 

25

A

 

 

 

2

(0.17, 1.7)

 

 

 

(0.056)

 

 

 

 

 

 

A

 

 

 

0

 

 

 

 

 

0

1

2

3

4

5

 

(3.8)

(7.6)

(11.4)

(15.1)

(18.9)

FLUID FLOW––gpm (lpm)

Test Fluid: No. 10 weight oil at 75_ F (23.9_ C)

To find fluid outlet pressure at a specific fluid flow and operating air pressure:

1.Locate desired fluid flow along bottom of chart.

2.Follow vertical line up to intersection with selected fluid outlet pressure curve (black).

3.Follow left to scale to read fluid outlet pressure.

To find pump air consumption at a specific fluid flow and air pressure:

1.Locate desired flow along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve (gray).

2. Follow right to scale to read air consumption.

307906 15

Page 15
Image 15