Message table

On-screen display

The following messages are displayed on the screen.

MESSAGE

Action

 

 

CHANGE THE LAMP

The lamp has been in service for long. Replacement with a new lamp is

AFTER REPLACING LAMP,

recommended. The lamp will go off automatically when the lamp replacement

RESET THE LAMP TIMER.

time is exceeded. *1

 

 

CHANGE THE LAMP

The total lamp service time will exceed the lamp replacement time in * hours.

AFTER REPLACING LAMP,

The lamp will go off automatically when the lamp replacement time is

RESET THE LAMP TIMER.

exceeded. Replace with a new lamp before that. *1

THE POWER WILL TURN

The asterisk (*) indicates the number of hours remaining before the lamp goes

OFF AFTER * Hr.

off automatically.

 

 

Blinking of

The total lamp service time has exceeded the lamp replacement time. The

lamp will go off automatically about 10 minutes after it starts blinking. Replace

CHANGE THE LAMP

with a new lamp.*2

 

 

 

NO INPUT IS DETECTED

Signal is hot input. (See page 20, 21)

 

 

SYNC IS OUT OF RANGE

The horizontal frequency of the input signal exceeds the range of the projector,

it cannot be displayed. (See page 21, 22)

 

 

 

*1 This message are not displayed after 3 minutes.

But this message are displayed when you turn on the power again.

*2 It is possible to again turn on the power, however the power will go off after about 10 minutes.

Indicator display

The ON indicator, LAMP indicator and TEMP indicator will light or blink in the following cases.

ON indicator

LAMP indicator

TEMP indicator

Meaning

 

 

Remedy

 

 

 

 

 

 

 

 

Lights orange

Goes off

Goes off

Standby mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinks green

Goes off

Goes off

During warming up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lights green

Goes off

Goes off

During operation *1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinks orange

Goes off

Goes off

During cooling down

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool projector by power off for 45

Lights red

Lights red

Goes off

Lamp cannot light *2

minutes.

If the indicator is still it, lamp may be

 

 

 

 

 

 

 

 

defective. Replace.

 

 

 

 

 

Lights red

Blinks red

Goes off

Lamp is not inserted or the

Securely insert the lamp or close the

lamp door open

lamp door.

 

 

 

Lights red

Goes off

Blinks red

Cooling fan accidented

Call a maintenance person.

 

 

 

 

 

 

 

 

 

 

 

The total lamp service time has

 

 

 

 

Blinks red

Blinks red

Goes off

exceeded the lamp

Call a maintenance person.

 

 

 

replacement time.

 

 

 

 

When the LAMP indicator lights, turn the power off. If the problem cannot be recovered, contact your dealer. *1 When the suction fan is stopped and the inside becomes hot, the power is cut automatically for cooling. (The

indicator light will go out.) In this case, turn off the power switch and allow the unit to cool down before turning the power switch on again. The lamp will light. If the lamp does not light because it is still automatically turned off, contact your dealer.

*2 If temperature inside the unit increases because of blocked vets, the lamp may go off for protection, and the LAMP indicator will turn red. Should this happen, turn off the main switch, wait until the set cools down (about 45 minutes), then again turn on the main switch.

32