WHATTO DO WHENYOUTHINK A MACHINE DEFECT HAS OCCURRED

Related Messages

When the unit's power is ON, messages such as those shown below may be displayed. When any such message is displayed on the screen, please respond as described below.

Message

Description

 

 

CHANGE THE LAMP

Lamp usage time is approaching 2,000 hours. (Note 2)

AFTER REPLACING LAMP,

Preparation of a new lamp, and an early lamp change, is

recommended. After you have changed the lamp, please be

RESET THE LAMP TIMER.

(Note 1)

sure to reset the lamp timer.

 

 

CHANGE THE LAMP

Lamp usage time is approaching 2,000 hours. A lamp change

within ** hours is recommended. (Note 2)

AFTER REPLACING LAMP,

When lamp usage reaches 2,000 hours, the power will

RESET THE LAMP TIMER.

automatically be turned OFF. Please change the lamp by

THE POWER WILL TURN OFF

referring to “THE LAMP” in Vol.1 (Basic). After you have

AFTER ** hr.

changed the lamp, please be sure to reset the lamp

(Note 1)

timer.

 

 

CHANGE THE LAMP

As lamp use has reached 2,000 hours, the power will soon be

automatically turned OFF. (Note 2)

AFTER REPLACING LAMP,

Please immediately turn the power OFF, and follow the

RESET THE LAMP TIMER.

instructions in the “THE LAMP” section of the separate booklet,

THE POWER WILL TURN OFF

Vol.1 (Basic).

After you have changed the lamp, please be sure to reset the

AFTER 0 hr.

 

lamp timer.

 

 

CLEAN THE AIR FILTER

A note of precaution when cleaning the air filter.

AFTER CLEANING AIR FILTER,

After cleaning the filter, operate FILTER TIME of the OPTION

RESET THE FILTER TIMER.

Menu, and perform reset of the filter timer.

 

 

NO INPUT IS DETECTED

There is no input signal.

Please confirm the signal input connection, and the status of the

ON ***

signal source.

 

 

 

SYNC IS OUT OF RANGE

The horizontal or vertical wavelength of the inputted signal is

outside of the response parameters of this unit. Please confirm

ON *** fH *****kHz fV *****Hz

the specs for this unit or the signal source specs.

 

The internal portion temperature is rising. Please turn the power

 

OFF, and allow the unit to cool down for approximately 20

 

minutes. After having confirmed the following items, then please

CHECK THE AIR FLOW

resent the power to ON.

 

• Is there blockage of the air passage aperture?

 

• Is the air filter dirty?

 

• Does the peripheral temperature exceed 35°C?

 

 

NOTES

Note 1: Although this message will be automatically disappeared after around 3 minutes, it will be reappeared every time the power is turned ON.

Note 2: Lamps have a finite product life. Lamps are characterized by the fact that, after long hours of usage, a lamp will no longer light up, or the lamp will break or burst, etc. This unit is equipped with an automatic shut-down function, such that the power will automatically be turned OFF when lamp usage time has reached 2,000 hours. Please be aware, however, that among lamp types, there are major differences in product lifetimes; a lamp may thus fail to light even prior to the functioning of the automatic shut-down function of this unit.