TROUBLESHOOTING

OSD Message

The messages as described below may appear on the screen at power ON. Take the appropriate measures when such a message appears.

Table 9. OSD Messages

Message

Contents

 

 

 

The message shown at left appears after the lamp has

CHANGE THE LAMP

been used for more than 1300 hours.

The lamp is approaching the end of its life.

AFTER REPLACING LAMP,

Power is switched OFF automatically when the lamp

RESET THE LAMP TIME.

reaches the end of its life. Prepare a new lamp for

*1)

 

installation.

 

Always reset the lamp timer after replacing the lamp.

 

 

CHANGE THE LAMP

The lamp will reach the end of its life in ** hours.

AFTER REPLACING LAMP,

RESET THE LAMP TIME.

Power will be switched OFF automatically in ** hours.

THE POWER WILL TURN OFF

Replace the lamp as shown in P.17~18 “Lamp”.

AFTER ** hr.

Always reset the lamp timer after replacing the lamp.

*1)

 

 

 

CHANGE THE LAMP

The lamp has reached the end of its life. Power will be

AFTER REPLACING LAMP,

switched OFF in a few minutes.

RESET THE LAMP TIME.

Switch power OFF immediately and replace the lamp as

THE POWER WILL

shown in P.17~18 “Lamp”.

TURN OFF

Always reset the lamp timer after replacing the lamp.

AFTER 0 hr.

 

 

 

NO INPUT IS DETECTED

No input signal found.

ON ***

Check signal input connections and signal sources.

 

 

 

The horizontal or vertical frequency of the input signal is

SYNC IS OUT OF RANGE

not within the specified range.

ON ***

Check the specifications of the equipment and the signal

 

source.

 

 

NOTE *1) This message is cleared automatically after approximately three minutes, and appears

every time power is switched ON.