TROUBLESHOOTING (continued)

Indicators Message

The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the appropriate measures.

Table 10. Indicators Message

POWER

LAMP

TEMP

Contents

indicator

indicator

indicator

 

 

 

 

 

Lights

Turns off

Turns off

The Standby mode has been set.

orange

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Warming up. Please wait.

green

 

 

 

 

 

 

 

Lights

Turns off

Turns off

ON. Normal operation possible.

green

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Cooling. Please wait.

orange

 

 

 

 

 

 

 

 

 

 

Cooling. Please wait.

Blinks red

-

-

The error is found. Take the appropriate measures when the

 

 

 

POWER indicator ceases blinking

 

 

 

Lamp is not lit.

Blinks

Lights

 

The interior of the equipment may be too hot. Switch power OFF,

Turns off

wait 20 minutes until the equipment cools, and check whether the

/Lights red

red

 

ventilation openings are blocked, whether the air filter is dirty, or

 

 

 

whether the ambient temperature exceeds 35 °C. And switch

 

 

 

power ON again. Replace the lamp if the same problem occurs.

 

 

 

 

Blinks

Blinks

 

Lamp or lamp cover is not found, or hasn’t been fitted in correctly.

Turns off

Switch power OFF, and wait for 45 minutes until the equipment

/Lights red

red

 

cools. Check fitting of the lamp and lamp cover, and switch power

 

 

 

ON again. Contact your dealer if the same problem occurs again.

 

 

 

 

Blinks

 

Blinks

The cooling fan is not operating.

Turns off

Switch power OFF, and wait for 20 minutes until the equipment

/Lights red

red

cools. Check for foreign matters in the fan, and switch power ON

 

 

 

again. Contact your dealer if the same problem occurs again.

 

 

 

 

 

 

 

The interior of the equipment is too hot. *2)

Blinks

 

 

Switch power OFF, and wait for 20 minutes until the equipment

Turns off

Lights red

cools. Check whether the ventilation openings are blocked,

/Lights red

 

 

whether the air filter is dirty, or whether the ambient temperature

 

 

 

exceeds 35 °C. Then switch power ON again. Contact your dealer if

 

 

 

the same problem occurs again.

 

 

 

 

Lights

Blinks

Blinks

The interior of the equipment is too cool.

Check whether the ambient temperature is below 0°C. Contact your

green

red

red

dealer if the same problem occurs when the ambient temperature is

 

 

 

0~35°C.

NOTE *2) When the internal temperature becomes excessive power is switched OFF automatically for safety reasons, and the indicator is extinguished. Set the power switch to [O] and wait for 20 minutes until the equipment has cooled sufficiently.

ENGLISH-20

Page 21
Image 21
Hitachi CPX275W user manual Troubleshooting, Indicators Message