Knob of the pressure reducer
Knob of the pressure switch
Joint | Pressure gauge |
|
Fig. 4
3.Shutdown
(1)Turn the knob of the pressure switch to “OFF”. (Fig. 1)
(2)Unplug the plug from power source.
(3)Open the drain cock located at the lower part of the tank (Fig. 5).
Drain cock
|
| Tank |
|
|
| Fig. 5 |
|
4. About the thermal protector |
| ||
( | This item is not necessary if your compressor is not | ) | |
equipped with the thermal protector reset switch | |||
shown in Fig. 6. | |||
| The thermal protector operates to stop the motor |
| |
| when a problem such as a motor overload, etc., |
| |
| occurs. If the motor should stop during operation, |
| |
| proceed as follows. |
| |
| (1) | Turn the pressure switch knob to the OFF position | |
|
| (Fig. 1) and disconnect the plug from the |
|
|
| receptacle. |
|
| (2) | If the extension cord does not conform to the |
|
|
| specifications given on page 6, replace with an |
|
|
| extension cord such as that shown on page 6. If |
|
|
| the capacity of the power supply is insufficient, |
|
|
| increase the power supply capacity to remove the | |
|
| cause of a flow of excessive current | |
| (3) | Wait approximately 5 minutes, then press the |
|
|
| reset switch of the thermal protector (Fig. 6). |
|
(4) Start up. If the motor still stops during operation, please contact the service center.
English
Reset switch of thermal protector
(EC6B) | (EC6C) |
Reset switch of thermal protector
(EC12) | (EC16) |
Fig. 6
MAINTENANCE
WARNING: Disconnect the compressor from the power source and remove the compressed air from the air tank before performing the maintenance operations.
1. Cleaning the intake filter
Remove the intake filter (Refer to Fig. 1.) every 50 hours or once a week and clean the inside of the intake filter and the filter element with compressed air. (Fig. 7)
Use a phillips screwdriver to disassemble intake filter models EC6B, EC6C and EC12. Use an allen wrench to disassemble model EC16.
WARNING: Never clean filter element with a flammable liquid or solvent.
— 11 —