Appendix
Page 27 of 36
B006 1011 1012 Phase loss detection enable X1 R/W 0 – 1
B007 1013 1014 Restart frequency threshold X100 R/W 0 – 40000
B012 1023 1024
Level of electronic thermal setting,
1st motor X10 R/W 200 – 1200
B212 1423 1424
Level of electronic thermal setting,
2nd motor X10 R/W 200 – 1200
B312 1623 1624
Level of electronic thermal setting,
3rd motor X10 R/W 200 – 1200
B013 1025 1026
Electronic thermal characteristic, 1st
motor X1 R/W 0 – 2
B213 1425 1426
Electronic thermal characteristic,
2nd motor X1 R/W 0 – 2
B313 1625 1626
Electronic thermal characteristic,
3rd motor X1 R/W 0 – 2
B015 1029 1030
Free setting electronic thermal
frequency 1 X1 R/W 0 – 400
B016 1031 1032
Free setting electronic thermal
current 1 X10 R/W 0 – 10000
B017 1033 1034
Free setting electronic thermal
frequency 2 X1 R/W 0 – 400
B018 1035 1036
Free setting electronic thermal
current 2 X10 R/W 0 – 10000
B019 1037 1038
Free setting electronic thermal
frequency 3 X1 R/W 0 – 400
B020 1039 1040
Free setting electronic thermal
current 3 X10 R/W 0 – 10000
B021 1041 1042
Overload restriction operation
mode X1 R/W 0 – 3
B022 1043 1044 Overload restriction setting X10 R/W 500 – 2000 *
B023 1045 1046
Deceleration rate at overload
restriction X100 R/W 10 – 3000
B024 1047 1048
Selection of method of overload
restriction 2 X1 R/W 0 – 3
B025 1049 1050 Overload restriction setting 2 X10 R/W 500 – 2000 *
B026 1051 1052
Deceleration rate at overload
restriction 2 X100 R/W 10 – 3000
B031 1061 1062 Software lock mode selection X1 R/W 0 – 10
B034 1067 1068 Run/power – on warning time X1 R/W 0 – 65535
B035 1069 1070 Rotational direction restriction X1 R/W 0 – 2
B036 1071 1072 Reduced voltage start selection X1 R/W 0 – 6
B037 1073 1074 Function code display restriction X1 R/W 0 – 2
B040 1079 1080 Torque limit selection X1 R/W 0 – 4
B041 1081 1082 Torque limit (I) forward driving X1 R/W 0 – 200 *
B042 1083 1084 Torque limit (II) reverse regen. X1 R/W 0 – 200 *
B043 1085 1086 Torque limit (III) reverse driving X1 R/W 0 – 200 *
B044 1087 1088 Torque limit (IV) forward regen. X1 R/W 0 – 200 *