1.Grip the lock at “A” position.

Even if the power plug is plugged in immediately after being unplugged, the compressor will not run for 10 minutes. However, if the inside is not cold, it will start running in approximately 10 minutes.

Replace spare parts.

1. Replace lamp

1. Unplug the refrigerator.

2. Remove shelves.

3. To take out the lamp cover, pull the lock at the position of “A”.

4.Remove the lamp, tightly screw the new lamp.

5.After replacing the lamp bulb, replace the lamp cover.

2.Pull Lamp-Cover

3.Pull Lamp-Cover

inclined slightly

by up direction.

by down direction.

 

Please do not pull Lamp-Cover by toward self-direction, because it might be cracked.