AUTOMATIC OPERATION
The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the initial room temperature. The selected mode of operation will not change when the room temperature varies.
RESET
Press the FUNCTION selector so that the display indicates the (AUTO) mode of operation.
1 | ● When AUTO has been selected, the device will automatically determine |
the mode of operation, HEAT, COOL or DEHUMIDIFY depending on |
the initial room temperature.
START | Press the |
| (START/STOP) button. | |
| ||||
Operation starts with a beep. | ||||
STOP | ||||
Press the button again to stop operation. |
■As the settings are stored in memory in the remote controller, you only have to press the (START/STOP) button next time.
You can raise or lower the temperature setting as necessary by maximum of 3°C.
|
|
| Press the temperature button and the temperature setting |
°C |
| ||
| will change by 1°C each time. | ||
|
|
| |
|
|
● The preset temperature and the actual room temperature may vary somewhat depending on conditions.
● The display does not indicate the preset temperature in the AUTO mode. If you change the setting, the indoor unit will produce a beep.
■Condition of Automatic Operation
Initial room temperature |
|
| Function | Temperature setting | FAN SPEED | |
(approx.) |
|
| ||||
|
|
|
|
| ||
|
|
|
|
|
| |
|
|
|
|
| HI at start, MED or LOW | |
Over 27°C | - |
| 27°C | |||
COOL | after the preset temperature | |||||
|
|
|
|
| is reached | |
|
|
|
|
| ||
|
|
|
| Slightly lower than the |
| |
23~27°C | - | DEHUMIDIFY | LOW | |||
room temperature | ||||||
|
|
| ||||
|
|
|
|
| ||
|
|
|
|
|
| |
|
|
|
|
| HI at start, MED or LOW | |
Under 23°C | - | HEAT | 23°C | |||
after the preset temperature | ||||||
|
|
| is reached | |||
|
|
|
|
|