– 6 –
Wash and rinse both sides of the knife by wiping outward from the center. Use a mild detergent or
sanitizer solution only. Never clean any part of the slicer with steel pads. Do not exceed chemical
manufacturer’s recommended concentrations for detergent or sanitizer. Do not exceed 200 parts
per million concentration of available chlorine. For example, mixing 1 tablespoon of 5.25% sodium
hypochlorite bleach with 1 gallon of water yields a solution containing 200 ppm of available chlorine.
Solution with concentrations greater than 200 ppm will accelerate corrosion of metals. Maximum
exposure to sanitizing solution varies with temperature and concentration. Rinse with clean water.
Reassemble the sharpener to the mounting
bracket by sliding the left slot on the sharpener
over the left guide pin on the bracket while tilting
slightly (Fig. 6). Then, press down on the right
side of the sharpener so the locking hole fits
over the right guide pin on the bracket. Slide the
Lock Lever to the right to lock the sharpener in
position. Make sure the sharpener is securely
engaged to the pins on the bracket.
Carefully reassemble the Top Knife Cover by
putting it in position (three guide pins). Lock by
turning the Latch Knob to the left while lowering
the Top Knife Cover; then, release the Latch
Knob and turn it to the right until snug.
Make sure the digits etched on the Key (Fig.
7) match the last t hree digit s of the sl icer
serial number. To reinstall the Carriage
Tray / Support Arm: Hold it with both hands
and lower it so the Key at the bottom of the
Support Arm fits into the slot of the Carriage
Pivot (Fig. 7). The Carriage Tray should rest
almost horizontal (Fig.3). Return the Carriage
Tray to the Gauge Plate by tilting to the left.
Turn the Knob on the Carriage Tray / Support
Arm clockwise until snug.
DO NOT wash any slicer componets in a
dishwasher. DO NOT immerse slicer b ase or
motor in water. DO NOT hose down slicer or
splash excessively with water.
If using a chlorinated sanitizing solution, dilute per manufacturer’s guidelines. Rinse with fresh
water.
NOTE: Failure to follow use, care, and maintenance instructions may void your Hobart warranty.
PL-41253-1
CARRIAGE PIVOT
CARRIAGE TRAY /
SUPPORTARM
KEY
Fig. 7
PL-41402-1
GAUGE PLATE
KNIFE
SHARPENER
LOCK LEVER
Fig. 6