– 5 –
SHARPENER
ROD & PIN
SHARPENER
MOUNT
SLOT
Fig. 4
ELECTRICAL
This machine is provided with a three-prong grounding plug. The outlet to which
this plug is connected must be properly grounded. If the receptacle is not the proper grounding
type, contact an electrician.
CLEAN BEFORE USING
The 3613 or 3713 slicer must be thoroughly cleaned and sanitized after installation and before being
used. Refer to Cleaning, pages 8 – 11.
TOP KNIFE COVER
The TOP KNIFE C OVER, and the plastic RING G UARD COVER underneath it, are shipped in place and secured
with the LATCH KNOB on the TOP KNIFE COVER (Fig. 7).
To remove the TOP KNIFE COVER, turn the LATCH KNOB (Fig. 7) counterclockwise and lift the TOP KNIFE
COVER off the three guide PINS (Figs. 5, 6). Remove the plastic RING GUARD COVER by lifting it from the
guide PINS (Fig. 6).
To reassemble the plastic RING
GUARD COVER on the RING G UARD,
position it using the three guide
PINS (Fig. 6). Then, reassemble
the TOP KNIFE COVER over the
plastic RING GUARD COVER;
position TOP KNIFE COVER using
the three guide PINS (Fig. 5).
Secure the RING GUARD COVER
and TOP KNIFE COVER by turning
the LATCH KNOB counterclockwise
while lowering the TOP KNIFE
COVER; then, release the LATCH
KNOB and turn it clockwise until
snug (Fig.7).
Fig. 5 Fig. 6
TOP KNIFE COVER
KNIFE
GAUGE PLATE
RING GUARD
COVER
PINS ON
RING GUARD
PLASTIC
RING
GUARD
COVER
KNIFE
(KNIFE COVER REMOVED)
SHARPENER
The SHARPENER is mounted on top of the slicer (Fig. 4). You can
remove it by lifting it straight up. Reinstall the SHARPENER by lowering
it back onto the SHARPENER MOUNT so the ROD AND PIN on the bottom
of the SHARPENER fit the SLOT in the SHARPENER MOUNT (Fig. 4). To use
the SHARPENER, refer to page 12.