Hobart 5212F manual Blade Guide, Electrical Connection

Models: 5212F

1 10
Download 10 pages 28.7 Kb
Page 6
Image 6
BLADE GUIDE

BLADE GUIDE

The blade guide in the lower guide and wiper assembly (Fig. 3) is available in additional sizes if using other than the standard .020" blade. Contact Service to change the blade guide for other widths.

ELECTRICAL CONNECTION

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT THE CIRCUIT IS BEING WORKED ON.

ELECTRICAL DATA

 

 

Fuse

 

Circuit Breaker

Model

Volts / Hertz / Phase

 

 

 

 

 

Minimum

 

Maximum

Minimum

Maximum

 

 

 

 

 

Circuit Ampacity

 

Fuse Size

Circuit Ampacity

Circuit Breaker Size

 

 

AMPS

 

AMPS

AMPS

AMPS

 

 

 

 

 

 

 

 

115 / 60 / 1

40

 

40

40

40

 

 

 

 

 

 

 

5212

200 - 230 / 60 / 1

25

 

25

30

30

5212F

 

 

 

 

 

 

200 - 230 / 60 / 3

15

 

15

20

20

 

 

 

 

 

 

 

 

 

 

460 / 60 / 3

15

 

6

15

10

 

 

 

 

 

 

 

Compiled in accordance with the National Electrical Code, ANSI / NFPA 70, 1993 Edition.

Remove the motor access panel (Fig. 5) on the left side of the meat saw (14 screws).

A13/32" diameter hole for 3/4" trade size conduit is located in the lower area of the base. Use watertight connections. Refer to Electrical Data, the machine data plate (Fig. 5), and the wiring diagram located inside the motor access panel when making the electrical connection. Use copper wire rated at least 75°C for the connection.

CHECK MOTOR ROTATION (Three-Phase Machines)

If the motor does not rotate so the teeth of the saw blade run downward as you look at the cutting zone, correct the rotation using the following procedure:

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.

Interchange any two of the incoming power supply leads. Reconnect the power supply and turn the saw momentarily on and off to verify correct rotation.

Replace the motor access panel (14 screws).

– 6 –

Page 6
Image 6
Hobart 5212F manual Blade Guide, Electrical Connection