Hobart 750 manual Installation, Specifications, Dimensions And Weight, Duty Cycle And Overheating

Models: 750

1 32
Download 32 pages 30.67 Kb
Page 13
Image 13

SECTION 2 – INSTALLATION

2-1. Specifications

 

Amperes Input at Rated Load

 

 

 

 

 

 

Maximum

 

 

 

 

 

 

Rated

Open-

 

 

Output 60 Hz

 

 

 

Type of

Plasma

Rated

Model

 

 

 

 

Cutting

Circuit

 

 

 

 

 

 

Output

Gas

Output

 

200 V

230 V

460 V

575 V

KVA

KW

Capacity

Voltage

 

 

 

 

 

 

 

 

 

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-

42.30

36.80

18.40

––

8.49

6.55

Direct

 

50 A @

 

 

Phase

(3.40*)

(2.95*)

(1.50*)

(0.68*)

(0.20*)

Current,

Air Or

0.7 in

 

 

110 Volts

280

 

 

 

 

 

 

 

Straight

Nitrogen

(18 mm)

 

 

18.40

9.20

7.40

7.32

6.60

DC, 60%

3-Phase

––

Polarity

Only

At 10 IPM

 

Duty Cycle

 

(2.13*)

(1.07*)

(0.85*)

(0.85*)

(0.32*)

(DCEN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling

2-2. Dimensions And Weight

C

B

A

Ref. 801 454-C

Dimensions

A36-3/4 in (934 mm)

B24-1/2 in (622 mm)

C

21 in (533 mm)

Weight

Single-Phase Models: 147 lb (66 kg)*

Three-Phase Models: 168 lb (76 kg)*

*Without Torch

2-3. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min- utes that unit can cut at rated load without overheating.

If unit overheats, thermostat(s)

60% Duty Cycleopens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before cutting.

Y Exceeding duty cycle can damage unit and void war- ranty.

6 Minutes Cutting

4 Minutes Resting

Overheating

0

A

 

15

 

OR

Minutes

Reduce Duty Cycle

duty1 4/95

OM-279 Page 9

Page 13
Image 13
Hobart 750 manual Installation, Specifications, Dimensions And Weight, Duty Cycle And Overheating