Hobart D300 manual Electrical Connection, Check Rotation Three-PhaseMachines Only

Models: D300

1 12
Download 12 pages 5.02 Kb
Page 4
Image 4
ELECTRICAL CONNECTION

ELECTRICAL CONNECTION

WARNING: ELECTRICAL AND GROUNDING CONNECTION MUST COMPLY WITH THE APPLICABLE PORTION OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.

ELECTRICAL DATA

Models

Volts / Hz / Ph

Rated Amps

Circuit Size

Fuse Size *

60°C Copper

Circuit Size

Circuit Breaker **

60°C Copper

 

 

 

(Amps)

(Amps)

Wire Size

(Amps)

(Amps)

Wire Size

 

 

 

 

 

 

 

 

 

D300

115 / 60 / 1

10.2

15

15

14

20

20

12

D300

200 / 60 / 1

5.6

15

6

14

15

10

14

D300

230 / 60 / 1

5.1

15

6

14

15

10

14

D300

200 / 60 / 3

2.1

15

3

14

15

3

14

D300

230 / 60 / 3

2.0

15

3

14

15

3

14

D300

460 / 60 / 3

1.0

15

1

14

15

1

14

 

 

 

 

* Dual Element

 

** Inverse Time

 

 

 

 

 

Time-Delay Fuse

 

Circuit Breaker

 

 

 

 

 

 

 

 

 

 

Circuit Size (Minimum) & Fuse / Circuit Breaker Size (Maximum) compiled in accordance with the National Electrical Code (ANSI/NFPA 70), 1993 Edition.

A hole for 34" trade size conduit is located at the bottom of the pedestal (Fig. 1). Make electrical connections to the pigtail leads per the wiring diagram supplied with the mixer.

Fig. 1

Check Rotation (Three-Phase Machines Only)

Three-phase machines must be connected so the planetary rotates in the direction of the arrow on the Drip Cup. To check rotation:

Set the gear shift lever on 1.

Apply power to the mixer, set the Electro-Mechanical Timer on HOLD; or, if equipped with a Programmable Timer Controller, set it on [ -- : -- ]. With the Bowl Support all the way up, momentarily run the machine by pushing the START and then STOP buttons.

If rotation is incorrect, DISCONNECT ELECTRICAL POWER SUPPLY and interchange any two of the incoming power supply leads.