Includes:

701 S Ridge Avenue, Troy, OH 45374

1-888-4HOBART • www.hobartcorp.com

FD3-150 FD3-200 FD3-300

FOODWASTE DISPOSERS

ELECTRICAL CONTROL GROUPS Listed by Underwriters Laboratories Inc., for use with FD3 Disposers (50 Hz. Electrical Specifications not UL listed)

Group 2 - For all Models

Includes:

Magnetic Contactors

Pushbutton Start and Stop

Automatic Reversing

NEMA 12 Enclosure

Solenoid Valve

Approximate

Shipping Wt. 31 lbs.

Group 3 - For all Models

Includes:

Magnetic Contactors

Pushbutton Start and Stop

Automatic Reversing

Low Water Pressure Cut-off

Time Delay for water after shut-off

Line disconnect

Solenoid Valve

NEMA 12 Enclosure

Approximate

Shipping Wt. 38 lbs.

Group 4 - For Model FD3-150

and FD3-200

Includes:

Manual Reversing Switch

NEMA 1 Enclosure or NEMA 4 Enclosure

Not available above 250 volts

Optional Solenoid Valve

Approximate

Shipping Wt. 11 lbs.

Model

H.P.

Ph.

Hz.

Volts

Rated Amps

 

 

 

 

 

 

 

FD3-150

 

112

1

60

120/208-240

17.2/8.2-8.6

 

112

3

60

208-240/480

4.8-4.8/2.4

 

 

FD3-200

2

1

60

120/208-240

20.0/10.0

 

 

 

 

 

2

3

60

208-240/480

6.8-6.5/3.3

 

 

 

 

 

 

 

 

 

FD3-300

3

3

60

208-240/480

9.0-8.0/4.0

 

 

 

 

 

 

 

FD3-150

112

1

50

110-120/220-240

See customer service

112

3

50

220-240/380-415

5.7-6.1/2.7-2.7

 

 

FD3-200

2

1

50

110-120/220-240

See customer service

 

 

 

 

 

2

3

50

220-240/380-415

6.7-7.0/3.4-3.4

 

 

 

 

 

 

 

 

 

FD3-300

3

3

50

220-240/380-415

9.0-8.7/4.8-4.6

 

 

 

 

 

 

 

The slant (/) indicates the dual voltage operation accomplished by motor lead connection: follow connecting diagram on motor.

SAMPLE SPECIFICATION

FD3-200 — B — 2 (240/60/3)

Electrical Specifications

Electrical Control Group

Accessory Group

Model Number

Cut hole 19” for 18” cone. Hole to be 16” for 15” cone. Solenoid must be installed in upright position.

Disposer may be easily rotated for better drain line connection.

Center line at wall outlet of trap should not be higher than center line of disposer discharge opening

If water pressure is in excess of 60 P.S.I. install a pressure reducing valve.

F-8560FD3-150 FD3-200 FD3-300 Foodwaste Disposers