LOCATION

Locate and identify the following components:

1.Hood and Fire Suppression System

2.Floor Stand and Contactor Box*

3.ANSULEX® Fire Suppressant, 1.5 gallon

4.Drip Cup

5.Grease Filter

6.Air Filter

7.Refillable Charcoal Filter

*Back Cover, Right Side Cover, Left Side Cover (optional)

LOCATION

The installation location must allow adequate clearances for servicing and proper operation. Minimum clearance at the right side and the rear of the unit is 0". A minimum clearance of 30" (76 cm) is required on the left side of the exhaust hood to permit operation of the manual actuator of the fire suppression system.

INSTALLATION CODES AND STANDARDS

The ventless exhaust hood and fire suppression system meets NFPA Standard #96, Vapor Removal from Cooking Equipment, without requiring a separate exhaust hood. The exhaust hood must be installed in accordance with:

In the United States of America:

1.State and local codes.

2.National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1.Local codes.

2.Canadian Electric Code, CSA C22.1 (latest edition). Copies may be obtained from The Canadian Standard Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3. (electric equipment)

ASSEMBLY

The exhaust hood is shipped in two pieces. Attach the hood to the frame as shown on page 2. The hood mounting screws will be found in the tapped holes in the floor stand.

Push the fryer beneath the hood. Lock casters or set leveling feet as required.

POSITIONING HOOD FILTERS

The three hood filters must be in their proper positions or your appliance will not function. Fig. 1 shows the long, welded pins (3 on the right and 3 on the left) against which the filters rest. Directly behind the pins on the left side are three shorter filter actuator switch pins which push in and out. Each filter must be placed so that it pushes its filter actuator switch pin in or your appliance will not operate.